The Destination IP address parameter can use both IP address and Domain Name. For some applications,
the user may need to send the data actively to the remote destination domain name.
Designated Local Port 1/2/3/4
Setting
TCP Port No.
Connection control
Setting
Startup/None, Any
Character/None,
Any Character/Inactivity Time,
DSR ON/DSR OFF, DSR ON/None,
DCD ON/DCD OFF, DCD ON/None
The meaning of each of the above settings is given in the table below. In general, both the Connect condition
and Disconnect condition are given.
Connect/Disconnect
Startup/None
(default)
Any Character/None
Any Character/
Inactivity Time
DSR On/DSR Off
DSR On/None
DCD On/DCD Off
DCD On/None
Factory Default
5011 (Port 1)
5012 (Port 2)
5013 (Port 3)
5014 (Port 4)
Factory Default
Startup/None
Description
A TCP connection will be established on startup, and will remain active indefinitely.
A TCP connection will be established when any character is received from the serial
interface, and will remain active indefinitely.
A TCP connection will be established when any character is received from the serial
interface, and will be disconnected when the Inactivity time out is reached.
A TCP connection will be established when a DSR "On" signal is received, and will
be disconnected when a DSR "Off" signal is received.
A TCP connection will be established when a DSR "On" signal is received, and will
remain active indefinitely.
A TCP connection will be established when a DCD "On" signal is received, and will
be disconnected when a DCD "Off" signal is received.
A TCP connection will be established when a DCD "On" signal is received, and will
remain active indefinitely.
5-22
Web Console Configuration
Necessity
Required
Necessity
Required