IE-CS(T)-2TX-xRS232/485
TCP alive check time
Setting
0 to 99 min
0 min: TCP connection is not closed due to an idle TCP connection.
1 to 99 min: The IE-CS(T)-2TX-xRS232/485 closes the TCP connection automatically if there is no TCP activity
for the given time.
Destination IP address
Setting
IP address or Domain Name
(E.g., 192.168.1.1)
TCP port No.
The Pair Connection "Master" will contact the network host that has this IP address. Data will be transmitted
through the port No. (4001 by default). Note that you must configure the same TCP port No. for the device
server acting as the Pair Connection "Slave."
Pair Connection Slave Mode
When you select Pair Connection Slave Mode for the Operation mode of one of the
IE-CS(T)-2TX-xRS232/485s this IE-CS(T)-2TX-xRS232/485 will be acting as a TCP server.
TCP alive check time
Setting
0 to 99 min
0 min: TCP connection is not closed due to an idle TCP connection.
1 to 99 min: The IE-CS(T)-2TX-xRS232/485 closes the TCP connection automatically if there is no TCP activity
for the given time.
Local TCP port
Setting
TCP port No. (e.g.,
4001)
This Port No. must be the same port No. that you set up for the Pair Connection "Master" device server
Factory Default
7 min
Factory Default
blank
4001
Factory Default
7 min
Factory Default
4001
5-26
Web Console Configuration
Necessity
Required
Necessity
Optional
Required
Necessity
Required
Necessity
Required