Weidmuller IE-CS-2TX-1RS232/485 User Manual

Industrial serial to ethernet converter
Hide thumbs Also See for IE-CS-2TX-1RS232/485:
Table of Contents

Advertisement

Quick Links

Industrial Serial to Ethernet Converter
User Manual for
IE-CS-2TX-1RS232/485
IE-CST-2TX-1RS232/485
IE-CS-2TX-2RS232/485
IE-CST-2TX-2RS232/485
First Edition, June 2011
1243270000/00/06.11

Advertisement

Table of Contents
loading

Summary of Contents for Weidmuller IE-CS-2TX-1RS232/485

  • Page 1 Industrial Serial to Ethernet Converter User Manual for IE-CS-2TX-1RS232/485 IE-CST-2TX-1RS232/485 IE-CS-2TX-2RS232/485 IE-CST-2TX-2RS232/485 First Edition, June 2011 1243270000/00/06.11...
  • Page 2 User Manual IE-CS(T)-2TX-xRS232/485 The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement. Copyright Notice Copyright ©2011 Weidmüller Interface GmbH & Co. KG All rights reserved. Reproduction without permission is prohibited.
  • Page 3: Table Of Contents

    Table of Contents Introduction............................1 Overview ..............................2 Package Checklist ..........................2 Product Features ...........................2 Product Specifications ..........................3 Getting Started .............................1 Panel Layout ............................2 Connecting the Hardware ........................2 Wiring Requirements ........................3 Connecting the Power ........................3 Connecting to the Network ......................4 Connecting to a Serial Device ......................4 LED Indicators ..........................4 Adjust the Pull-high/Pull-low Resistors and Terminators for RS-422/RS-485 Ports ........4 Initial IP Address Configuration......................1...
  • Page 4 Unlock Password Protection ......................5 Configuring the IE-CS(T)-2TX-xRS232/485..................7 Upgrading the Firmware ........................8 Export Configuration........................9 Import Configuration ........................9 Monitor ..............................9 Port Monitor ............................13 COM Mapping ............................14 On-line COM Mapping ........................14 Off-line COM Mapping ........................18 COM Grouping............................. 18 Creating a COM Group ........................18 Deleting a COM Group ........................
  • Page 5: Introduction

    Welcome to the IE-CS(T)-2TX-xRS232/485 of industrial Serial/Ethernet converters. In this manual, we refer to the 4 products in the series collectively as the “IE-CS(T)-2TX-xRS232/485 Series.” The four models in the IE-CS(T)-2TX-xRS232/485 Series are: IE-CS-2TX-1RS232/485 1-port RS-232/422/485 industrial serial Ethernet converter with serial/LAN/power surge protection, two 10/100BaseT(X) ports (1 IP), 0 to 60°C...
  • Page 6: Overview

    IE-CS(T)-2TX-xRS232/485 Introduction Overview These advanced Serial/Ethernet converters are more rugged than ever before, from the design, casing, connectors, mounting methods, to the surge protection. Not only has the hardware been upgraded, but more flexible and user-friendly software has been added. The IE-CS(T)-2TX-xRS232/485 series deliver easy and reliable serial-to-Ethernet connectivity for the industrial automation market.
  • Page 7: Product Specifications

    IE-CS(T)-2TX-xRS232/485 Introduction Product Specifications Ethernet Interface Number of Ports: 2 Speed: 10/100 Mbps, auto MDI/MDIX Connector: 8-pin RJ45 Magnetic Isolation Protection: 1.5 KV built-in Serial Interface Number of Ports: IE-CS(T)-2TX-1RS232/485: 1 IE-CS(T)-2TX-2RS232/485: 2 Serial Standards: RS-232/422/485 Connector: IE-CS(T)-2TX-1RS232/485: DB9 male for RS-232, terminal block for RS-422/485 IE-CS(T)-2TX-2RS232/485: DB9 male for RS-232/422/485 Serial Line Protection: •...
  • Page 8 IE-CS(T)-2TX-xRS232/485 Introduction Power Consumption: IE-CS(T)-2TX-1RS232/485: 12 to 48 VDC, 220 mA @ 12 VDC; 110 mA @ 24 VDC IE-CS(T)-2TX-2RS232/485: 12 to 48 VDC, 250 mA @ 12 VDC; 125 mA @ 24 VDC Regulatory Approvals EMC: CE (EN55022 Class A, EN55024), FCC Part 15 Subpart B Class A Safety: UL508, LVD Hazardous Location: UL/cUL Class 1 Division 2 Groups A, B, C and D ATEX: Class I, Zone 2...
  • Page 9: Getting Started

    Getting Started In this chapter, we give instructions on installing the IE-CS(T)-2TX-xRS232/485 Serial/Ethernet converters. Software installation is covered in subsequent chapters. The following topics are covered in this chapter:  Panel Layout  Connecting the Hardware  Wiring Requirements  Connecting the Power ...
  • Page 10: Panel Layout

    IE-CS(T)-2TX-xRS232/485 Getting Started Panel Layout IE-CS(T)-2TX-1RS232/485 IE-CS(T)-2TX-2RS232/485 Connecting the Hardware This section describes how to connect the IE-CS(T)-2TX-xRS232/485 to serial devices for first time testing purposes. We cover Wiring Requirements, Connecting the Power, Grounding the IE-CS(T)-2TX-xRS232/485, Connecting to the Network, Connecting to a Serial Device, and LED Indicators.
  • Page 11: Wiring Requirements

    IE-CS(T)-2TX-xRS232/485 Getting Started Wiring Requirements ATTENTION Safety First! Be sure to disconnect the power cord before installing and/or wiring your IE-CS(T)-2TX-xRS232/485. Wiring Caution! Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allowable for each wire size. If the current goes above the maximum ratings, the wiring could overheat, causing serious damage to your equipment.
  • Page 12: Connecting To The Network

    IE-CS(T)-2TX-xRS232/485 Getting Started Connecting to the Network Connect one end of the Ethernet cable to the IE-CS(T)-2TX-xRS232/485’s 10/100M Ethernet port and the other end of the cable to the Ethernet network. If the cable is properly connected, the IE-CS(T)-2TX-xRS232/485 will indicate a valid connection to the Ethernet in the following ways: •...
  • Page 13 IE-CS(T)-2TX-xRS232/485 Getting Started the various environments and this is why the IE-CS(T)-2TX-xRS232/485 provides DIP switches for setting the pull high/low resistor values for each serial port. The DIP switches are located on the PCB board; you will need to take off the covers to access them. To set the pull-high resistor to 150 KΩ, flip DIP1 to “OFF,”...
  • Page 14: Initial Ip Address Configuration

    Initial IP Address Configuration When setting up your IE-CS(T)-2TX-xRS232/485 for the first time, the first thing you should do is configure the IP address. This chapter introduces the methods that can be used to configure the IE-CS(T)-2TX-xRS232/485’s IP address. Select one of the initial IP Address configuration methods to configure the IE-CS(T)-2TX-xRS232/485’s IP Address.
  • Page 15: Initializing The Ie-Cs(T)-2Tx-Xrs232/485'S Ip Address

    IE-CS(T)-2TX-xRS232/485 Initial IP Address Configuration Initializing the IE-CS(T)-2TX-xRS232/485’s IP Address Determine whether your IE-CS(T)-2TX-xRS232/485 needs to use a Static IP or Dynamic IP (either DHCP or BOOTP application). If the IE-CS(T)-2TX-xRS232/485 is used in a Static IP environment, you can use the S/E-Converter Administrator, Web Console, Telnet Console, or Serial Console to configure the new IP address.
  • Page 16: Telnet Console

    IE-CS(T)-2TX-xRS232/485 Initial IP Address Configuration Telnet Console Depending on how your computer and network are configured, you may find it convenient to use network access to set up your IE-CS(T)-2TX-xRS232/485’s IP address. This can be done using Telnet. ATTENTION Figures in this chapter were generated using IE-CS-2TX-2RS232/485. 1.
  • Page 17 IE-CS(T)-2TX-xRS232/485 Initial IP Address Configuration 5. Type 1 to select IP address and then press Enter. 6. Use the Backspace key to erase the current IP address, type in the new IP address, and then press Enter. 7. Press any key to continue…...
  • Page 18: Serial Console (19200, N, 8, 1)

    IE-CS(T)-2TX-xRS232/485 Initial IP Address Configuration 8. Type m and then press Enter to return to the main menu. 9. Type s and then press Enter to Save/Restart the system. 10. Type y and then press Enter to save the new IP address and restart the IE-CS(T)-2TX-xRS232/485. Serial Console (19200, n, 8, 1) You may use the RS-232 console port to set up the IP address for the IE-CS(T)-2TX-xRS232/485.
  • Page 19 IE-CS(T)-2TX-xRS232/485 Initial IP Address Configuration 3. Start Hyper Terminal and enter a name of your choice for the new connection. Select the appropriate COM port for console connection in the “New Connection” window. 4. Select following Communication Parameter for the console connection: 19200 for Bits per second, 8 for Data Bits, None for Parity, and 1 for Stop Bits and None for Flow control.
  • Page 20 IE-CS(T)-2TX-xRS232/485 Initial IP Address Configuration 7. Input the password when prompted. Note that this page will only appear when the IE-CS(T)-2TX-xRS232/485 has been set up for password protection. 8. Start configuring the IP address under Network Settings. Refer to step 4 in the Telnet Console section for the rest of the IP settings.
  • Page 21: Choosing The Proper Operation Mode

    Choosing the Proper Operation Mode In this chapter, we describe the IE-CS(T)-2TX-xRS232/485 various operation modes. The options include an operation mode that uses a driver installed on the host computer, and operation modes that rely on TCP/IP socket programming concepts. After choosing the proper operation mode in this chapter, refer to Chapter 5 for detailed configuration parameter definitions.
  • Page 22: Overview

    IE-CS(T)-2TX-xRS232/485 Choosing the Proper Operation Mode Overview IE-CS(T)-2TX-xRS232/485 serial device servers network-enable traditional RS-232/422/485 devices, in which a Serial Device Server is a tiny computer equipped with a CPU, real-time OS, and TCP/IP protocols that can bi-directionally translate data between the serial and Ethernet formats. Your computer can access, manage, and configure remote facilities and equipment over the Internet from anywhere in the world.
  • Page 23: Rfc2217 Mode

    IE-CS(T)-2TX-xRS232/485 Choosing the Proper Operation Mode ATTENTION Real COM Mode allows several hosts to have access control over the same IE-CS(T)-2TX-xRS232/485. The driver that comes with your IE-CS(T)-2TX-xRS232/485 controls host access to attached serial devices by checking the host’s IP address. Refer to Accessible IP Settings in Chapter 5 for more details. RFC2217 Mode RFC2217 mode is similar to Real COM mode in that a driver is used to establish a transparent connection between a host computer and a serial device by mapping the serial port on the IE-CS(T)-2TX-xRS232/485 to...
  • Page 24: Udp Mode

    IE-CS(T)-2TX-xRS232/485 Choosing the Proper Operation Mode UDP Mode Compared to TCP communication, UDP is faster and more efficient. In UDP mode, you can not only unicast but also multicast data from the serial device to multiple host computers, and the serial device can also receive data from multiple host computers, making this mode ideal for message display applications.
  • Page 25: Disabled Mode

    IE-CS(T)-2TX-xRS232/485 Choosing the Proper Operation Mode Console management is commonly used by connecting to Console/AUX or COM ports of routers, switches, and UPS units. Rtelnet works the same as RAW mode in that only one TCP port is listened to after booting up. The system then waits for a host on the network to initiate a connection.
  • Page 26: Web Console Configuration

    Web Console Configuration The Web Console is the most user-friendly method available to configure the IE-CS(T)-2TX-xRS232/485. In this chapter, we will introduce the Web Console function groups and function definitions. The following topics are covered in this chapter:  Opening Your Browser ...
  • Page 27: Opening Your Browser

    IE-CS(T)-2TX-xRS232/485 Web Console Configuration Opening Your Browser 1. Open your browser with the cookie function enabled. (To enable your browser for cookies, right click on your desktop Internet Explorer icon, select Properties, click on the Security tab, and then select either Enable or Prompt as shown in the figure below.) 2.
  • Page 28 IE-CS(T)-2TX-xRS232/485 Web Console Configuration 2. The following sections introduce these two convenient functions and the other settings listed in the Main Menu on the left of the page. ATTENTION If you forgot the password, the ONLY way to start configuring the IE-CS(T)-2TX-xRS232/485 is to load the factory defaults by using the "Reset to default"...
  • Page 29 IE-CS(T)-2TX-xRS232/485 Web Console Configuration 2. In the Step 2/3, you must specify the operation mode you will be using. If your operation mode is not Real COM, TCP Server, TCP Client, or UDP mode, click Cancel and to go back to main menu and choose Operating Settings to select suitable settings.
  • Page 30: Export/Import

    IE-CS(T)-2TX-xRS232/485 Web Console Configuration Export/Import Export/Import allows you to back up and recover your settings. Click Export, to store all configuration data into a default file, <Servername>.txt. Click the Import button to upload a configuration file to the IE-CS(T)-2TX-xRS232/485. Basic Settings...
  • Page 31: Network Settings

    IE-CS(T)-2TX-xRS232/485 Web Console Configuration Server name Setting Factory Default Necessity 1 to 39 characters NP[model name]_[Serial No.] Optional Web/Telnet Console The Disable option for “Web console” and “Telnet console” is included for security reasons. In some cases, you may want to disable one or both of these console utilities as an extra precaution to prevent unauthorized users from accessing your IE-CS(T)-2TX-xRS232/485.
  • Page 32 IE-CS(T)-2TX-xRS232/485 Web Console Configuration IE-CS(T)-2TX-xRS232/485 will not have a valid connection to the network). First time users may refer to Chapter 3, Initial IP Address Configuration, for more information. You can choose from four possible IP Configuration modes—Static, DHCP, DHCP/BOOTP, and BOOTP—located under the web console screen’s IP configuration drop-down box.
  • Page 33: Snmp Settings

    IE-CS(T)-2TX-xRS232/485 Web Console Configuration ATTENTION In Dynamic IP environments, the firmware will retry every 30 seconds, up to three times, until network settings are assigned by the DHCP or BOOTP server. The timeout for each try increases from one second, to three seconds, then to give seconds.
  • Page 34: Ip Address Report

    IE-CS(T)-2TX-xRS232/485 Web Console Configuration IP Address Report When IE-CS(T)-2TX-xRS232/485 products are used in a dynamic IP environment, users need to spend more time with IP management tasks. For example, if the IE-CS(T)-2TX-xRS232/485 works as a server (TCP or UDP), then the host, which acts as a client, must know the IP address of the server. If the DHCP server assigns a new IP address to the IE-CS(T)-2TX-xRS232/485, the host needs a way to determine the IE-CS(T)-2TX-xRS232/485’s new IP address.
  • Page 35: Serial Parameters

    IE-CS(T)-2TX-xRS232/485 Web Console Configuration To modify the serial settings for a specific port, click Port X (X=1 or 2) under Serial Settings. Port alias Setting Factory Default Necessity 1 to 15 characters None Optional (E.g., PLC-No.1) “Port alias” is included to allow easy identification of the serial devices that are connected to the IE-CS(T)-2TX-xRS232/485’s serial ports.
  • Page 36: Operating Settings

    IE-CS(T)-2TX-xRS232/485 Web Console Configuration Flow control Setting Factory Default Necessity None, RTS/CTS, RTS/CTS Required DTR/DSR, Xon/Xoff FIFO Setting Factory Default Necessity Enable, Disable Enable Required The IE-CS(T)-2TX-xRS232/485’s serial ports provide a 16-byte FIFO in the Tx and Rx directions. To prevent unexpected communication, disable the FIFO setting if your serial device does not offer FIFO.
  • Page 37 IE-CS(T)-2TX-xRS232/485 Web Console Configuration TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Optional 0 min: TCP connection is not closed due to an idle TCP connection. 1 to 99 min: the IE-CS(T)-2TX-xRS232/485 will automatically close the TCP connection if there is no TCP activity during this given time.
  • Page 38 IE-CS(T)-2TX-xRS232/485 Web Console Configuration Allow driver control Setting Factory Default Necessity No or Yes Optional If “Max connection” is greater than 1, IE-CS(T)-2TX-xRS232/485 will ignore the driver control commands from all connected hosts. However, if you set “Allow driver control” to “Yes,” control commands will be accepted. Note: Since the IE-CS(T)-2TX-xRS232/485 may get configuration changes from multiple hosts, the most recent command it receives will take precedence.
  • Page 39: Rfc2217 Mode

    IE-CS(T)-2TX-xRS232/485 Web Console Configuration data in its internal buffer. The IE-CS(T)-2TX-xRS232/485 transmits the data stored in the buffer via TCP/IP, but only if the internal buffer is full or if the Force transmit time interval reaches the time specified under the Force transmit timeout.
  • Page 40 IE-CS(T)-2TX-xRS232/485 Web Console Configuration 0 to 1024 Optional Default = 0: The Delimiter Process will be followed, regardless of the length of the data packet. If the data length (in bytes) matches the configured value, the data will be forced out. The data length can be configured for 0 to 1024 bytes.
  • Page 41: Tcp Server Mode

    IE-CS(T)-2TX-xRS232/485 Web Console Configuration TCP Server Mode TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Optional 0 min: TCP connection is not closed due to an idle TCP connection. 1 to 99 min: The IE-CS(T)-2TX-xRS232/485 will automatically close the TCP connection if there is no TCP activity during this given time.
  • Page 42 IE-CS(T)-2TX-xRS232/485 Web Console Configuration Max connection is usually used when the user needs to receive data from different hosts simultaneously. The factory default only allows 1 connection at a time. Max connection 1: IE-CS(T)-2TX-xRS232/485 only allows 1 host to open the TCP connection to the specific serial port. Max connection 2 to 8: Allows two to eight host’s TCP connection request to open this IE-CS(T)-2TX-xRS232/485 serial port, at the same time.
  • Page 43 IE-CS(T)-2TX-xRS232/485 Web Console Configuration ATTENTION Delimiter 2 is optional. If left blank, then Delimiter 1 alone trips the clearing of the buffer. If the size of the serial data received is greater than 1 KB, the IE-CS(T)-2TX-xRS232/485 will automatically pack the data and send it to the Ethernet.
  • Page 44: Tcp Client Mode

    IE-CS(T)-2TX-xRS232/485 Web Console Configuration Command port Setting Factory Default Necessity 1 to 65535 Optional The “Command port” is a listening TCP port that received IP-Serial Lib commands from the host. In order to prevent a TCP port conflict with other applications, the user can set the Command port to another port as needed.
  • Page 45 IE-CS(T)-2TX-xRS232/485 Web Console Configuration closed down unintentionally. The IE-CS(T)-2TX-xRS232/485 will then force the existing TCP connection to close. ATTENTION The Inactivity time should be configured to be larger than the Force transmit timeout setting. To prevent the unintended loss of data due to the session disconnection, it is highly recommended that you set this value large enough so that the intended data transfer is completed.
  • Page 46 IE-CS(T)-2TX-xRS232/485 Web Console Configuration Delimiter process Setting Factory Default Necessity Do Nothing, Do Nothing Optional Delimiter + 1, Delimiter + 2, Strip Delimiter Delimiter + 1 or Delimiter + 2: The data will be transmitted when an additional byte (for Delimiter +1), or an additional 2 bytes (for Delimiter +2) of data is received after receiving the Delimiter.
  • Page 47 IE-CS(T)-2TX-xRS232/485 Web Console Configuration ATTENTION The Destination IP address parameter can use both IP address and Domain Name. For some applications, the user may need to send the data actively to the remote destination domain name. Designated Local Port 1/2/3/4 Setting Factory Default Necessity...
  • Page 48: Udp Mode

    IE-CS(T)-2TX-xRS232/485 Web Console Configuration UDP Mode Packing length Setting Factory Default Necessity 0 to 1024 Optional Default = 0, The Delimiter Process will be followed, regardless of the length of the data packet. If the data length (in bytes) matches the configured value, the data will be forced out. The data length can be configured for 0 to 1024 bytes.
  • Page 49 IE-CS(T)-2TX-xRS232/485 Web Console Configuration Strip Delimiter: When the Delimiter is received, the Delimiter is deleted (i.e., stripped), and the remaining data is transmitted. Do Nothing: The data will be transmitted when the Delimiter is received. Force transmit Setting Factory Default Necessity 0 to 65535 ms 0 ms...
  • Page 50: Pair Connection Mode

    IE-CS(T)-2TX-xRS232/485 Web Console Configuration UDP Multicast A multicast is a packet sent by one host to multiple hosts. In multicast, each host that belongs to a specific multicast group will receive multicast packets for that group. To configure a host as a multicast receiver over the Internet, it must inform the routers on its LAN.
  • Page 51 IE-CS(T)-2TX-xRS232/485 Web Console Configuration TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Required 0 min: TCP connection is not closed due to an idle TCP connection. 1 to 99 min: The IE-CS(T)-2TX-xRS232/485 closes the TCP connection automatically if there is no TCP activity for the given time.
  • Page 52: Ethernet Modem Mode

    IE-CS(T)-2TX-xRS232/485 Web Console Configuration Ethernet Modem Mode Dial-in The IE-CS(T)-2TX-xRS232/485 listens for a TCP/IP connection request from the remote Ethernet modem or host. IE-CS(T)-2TX-xRS232/485’s response depends on the ATS0 value, as outlined below. ATS0=0 (default): The IE-CS(T)-2TX-xRS232/485 will temporarily accept the TCP connection and then send the “RING” signal out through the serial port.
  • Page 53 IE-CS(T)-2TX-xRS232/485 Web Console Configuration AT Commands The IE-CS(T)-2TX-xRS232/485 supports the following common AT commands used with a typical modem: AT command Description Remarks Answer manually ATD <IP>:<Port> Dial up the IP address: Port No. ATE0=Echo OFF ATE1=Echo ON (default) ATH0=On-hook (default) ATH1=Off-hook ATI, ATI0, ATI1, ATI2 Modem version...
  • Page 54: Reverse Telnet Mode

    IE-CS(T)-2TX-xRS232/485 Web Console Configuration (always=14, unit 1/10 sec) DTMF duration and spacing (always=100 ms) no action applied Escape code guard time (default=50, unit 1/50 sec) to control the idle time for “+++” TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Required...
  • Page 55: Disabled Mode

    IE-CS(T)-2TX-xRS232/485 Web Console Configuration Each of the IE-CS(T)-2TX-xRS232/485’s serial ports is mapped to a TCP port. To avoid conflicts with common TCP port numbers, set port numbers to 4001 for port 1, 4002 for port 2, etc. Map <CR-LF> Setting Factory Default Necessity CR, LF, or CR-LF...
  • Page 56: Accessible Ip Settings

    IE-CS(T)-2TX-xRS232/485 Web Console Configuration Accessible IP Settings The IE-CS(T)-2TX-xRS232/485 uses an IP address based filtering method to control access to itself. Accessible IP Settings allows you to add or block remote host IP addresses to prevent unauthorized access. Access to the IE-CS(T)-2TX-xRS232/485 is controlled by IP address. That is, if a host’s IP address is in the accessible IP table, then the host will be allowed to access the IE-CS(T)-2TX-xRS232/485.
  • Page 57: Auto Warning Settings

    IE-CS(T)-2TX-xRS232/485 Web Console Configuration Auto Warning Settings Auto warning: Email and SNMP trap Mail Server Mail server Setting Factory Default Necessity IP Address or Domain None Optional Name User name Setting Factory Default Necessity 1 to 15 characters None Optional Password Setting Factory Default...
  • Page 58: Event Type

    IE-CS(T)-2TX-xRS232/485 Web Console Configuration SNMP Trap Server SNMP trap server IP or domain name Setting Factory Default Necessity IP address or Domain None Optional Name Event Type Cold start This refers to starting the system from power off (contrast this with warm start). When performing a cold start, the IE-CS(T)-2TX-xRS232/485 will automatically issue an Auto warning message by e-mail, or send an SNMP trap after booting up.
  • Page 59 IE-CS(T)-2TX-xRS232/485 Web Console Configuration Power failure We provide two DC power inputs for redundancy. The IE-CS(T)-2TX-xRS232/485 supports different approaches to warn engineers automatically, such as by email or relay output. Users can connect to “Monitor -> Relay Output” from the web console to check what event causes the warning. The relay output will be canceled after the power recovers, or by selecting “acknowledge event”...
  • Page 60: Upgrade Firmware

    IE-CS(T)-2TX-xRS232/485 Web Console Configuration Upgrade Firmware Keep your IE-CS(T)-2TX-xRS232/485 up to date with the latest firmware from Weidmüller. Occasionally, compare your IE-CS(T)-2TX-xRS232/485 firmware to the version currently available at the Weidmüller website (www.weidmueller.com), If there is a new firmware version, you can download it and click Import to upgrade your firmware.
  • Page 61: Monitor Async

    IE-CS(T)-2TX-xRS232/485 Web Console Configuration Monitor Async Click Async under Monitor to show the current status of the serial port. Monitor Async-Settings Click Async Setting under Monitor to show the run-time settings for the serial port. 5-36...
  • Page 62: Monitor Relay Output

    IE-CS(T)-2TX-xRS232/485 Web Console Configuration Monitor Relay Output Click Relay Output under Monitor to show the current status of the relay output. To cease the Relay Output warning, click on the Acknowledge Event button. Change Password Input the “Old password” and “New password” to change the password. Leave the password boxes blank to erase the password.
  • Page 63: Load Factory Default

    IE-CS(T)-2TX-xRS232/485 Web Console Configuration Load Factory Default This function will reset all of IE-CS(T)-2TX-xRS232/485’s settings to the factory default values. Be aware that previous settings will be lost. Save/Restart Click Save/Restart will save the current configured settings and restart IE-CS(T)-2TX-xRS232/485 to take effect.
  • Page 64: Configuring S/E Converter Administrator

    Configuring S/E Converter Administrator The following topics are covered in this chapter:  Overview  Installing S/E-Converter Administrator  Configuration  Broadcast Search  Unlock Password Protection  Configuring the IE-CS(T)-2TX-xRS232/485  Upgrading the Firmware  Export Configuration  Import Configuration ...
  • Page 65: Overview

    IE-CS(T)-2TX-xRS232/485 IP Serial LIB Overview S/E-Converter Administrator lets you install and configure your IE-CS(T)-2TX-xRS232/485 products easily over the network. Five function groups are provided to ease the installation process, allow off-line COM mapping, and provide monitoring and IP location server functions. Weidmüller SE-Converter Administraton is an integrated software suite that bundles SE-Converter Administrator and the IP Serial Library, and provides everything you need to manage, monitor, and modify your IE-CS(T)-2TX-xRS232/485 from a remote location.
  • Page 66 IE-CS(T)-2TX-xRS232/485 IP Serial LIB 4. Click Install to proceed with the installation. 5. The Installing window reports the progress of the installation. 6. Click Next to proceed with the installation. 7. Click Finish to complete the installation of S/E-Converter Administrator.
  • Page 67: Configuration

    IE-CS(T)-2TX-xRS232/485 IP Serial LIB Configuration The Administrator-Configuration window is divided into four parts. • The top section contains the function list and online help area. (Windows NT does not support this .chm file format.) • The five Administrator function groups are listed in the left section. •...
  • Page 68: Unlock Password Protection

    IE-CS(T)-2TX-xRS232/485 IP Serial LIB 2. The Broadcast Search window will open and display the Model, IP Address, MAC Address, and Progress of the search for that particular device. 3. When the search is complete, the Broadcast Search window will close, and the IE-CS(T)-2TX-xRS232/485s that were located will be displayed in the right pane of the Administrator window.
  • Page 69 IE-CS(T)-2TX-xRS232/485 IP Serial LIB 1. Select the IE-CS(T)-2TX-xRS232/485 with “Lock” status, click the right mouse button, and then select Unlock. 2. After inputting the correct password, the Administrator will display an “Unlock ok” message. 3. The “Lock” status will change to “Unlock,” and the Administrator utility will keep this IE-CS(T)-2TX-xRS232/485 in the Unlock status throughout this Administrator session.
  • Page 70: Configuring The Ie-Cs(T)-2Tx-Xrs232/485

    IE-CS(T)-2TX-xRS232/485 IP Serial LIB Lock Fixed The IE-CS(T)-2TX-xRS232/485 is password protected, “Specify by IP address” was used to locate it, and the password has not yet been entered from within the current Administrator session. Unlock Fixed The IE-CS(T)-2TX-xRS232/485 is password protected, “Specify by IP address” was used to locate it, and the password has been entered from within the current Administrator session.
  • Page 71: Upgrading The Firmware

    IE-CS(T)-2TX-xRS232/485 IP Serial LIB ATTENTION You can simultaneously modify the configurations of multiple IE-CS(T)-2TX-xRS232/485 that are of the same model. To select multiple IE-CS(T)-2TX-xRS232/485s, hold down the Ctrl key when selecting additional IE-CS(T)-2TX-xRS232/485s, or hold down the Shift key to select a group of IE-CS(T)-2TX-xRS232/485s. Upgrading the Firmware Follow these steps to upgrade the firmware of an IE-CS(T)-2TX-xRS232/485.
  • Page 72: Export Configuration

    IE-CS(T)-2TX-xRS232/485 IP Serial LIB Export Configuration To export the configuration of an IE-CS(T)-2TX-xRS232/485, right click the IE-CS(T)-2TX-xRS232/485, select Export Configuration, and then follow the onscreen instructions. The Export Configuration function is a handy tool that can be used to produce a text file containing the current configuration of a particular IE-CS(T)-2TX-xRS232/485.
  • Page 73 IE-CS(T)-2TX-xRS232/485 IP Serial LIB 1. With Configuration selected under Function, use Broadcast Search to locate all IE-CS(T)-2TX-xRS232/485 on your LAN. 2. Next, click Monitor  Add Target and select your targets from the list, and then click OK. Once the Monitor function is running: 3.
  • Page 74 IE-CS(T)-2TX-xRS232/485 IP Serial LIB 4. Right click the panel and select Settings. 5. Select or de-select Monitor Items. Use the single arrowhead buttons to move highlighted items from one box to the other. Use the double arrowhead buttons to move all items in one box to the other. 6.
  • Page 75 IE-CS(T)-2TX-xRS232/485 IP Serial LIB “Not Alive,” or has lost connection with the Monitor program. 8. Right click in the IE-CS(T)-2TX-xRS232/485 list section and select Go to start Monitoring the IE-CS(T)-2TX-xRS232/485. 9. For this example, the IE-CS(T)-2TX-xRS232/485 shown in the list will be monitored. 10.
  • Page 76: Port Monitor

    IE-CS(T)-2TX-xRS232/485 IP Serial LIB 11. In the Monitor screen, you can see that the IE-CS(T)-2TX-xRS232/485s that are “Not Alive” are shown in red color. 12. If the IE-CS(T)-2TX-xRS232/485 gets reconnected, a warning will be displayed to remind the user that the IE-CS(T)-2TX-xRS232/485 is now “Alive.”...
  • Page 77: Com Mapping

    IE-CS(T)-2TX-xRS232/485 IP Serial LIB COM Mapping Windows Administration Suite comes with Windows 95/98/ME/NT/2000/XP/7 Real COM drivers. After you install S/E-Converter Administrator, there are two ways to set up the IE-CS(T)-2TX-xRS232/485 serial port as your host’s remote COM port. The first way is with On-line COM Mapping. On-line COM Mapping will check to make sure that the IE-CS(T)-2TX-xRS232/485 is connected correctly to the network and then install the driver on the host computer.
  • Page 78 IE-CS(T)-2TX-xRS232/485 IP Serial LIB 3. Add the target to which you would like to map COM ports. 4. The IE-CS(T)-2TX-xRS232/485 list that appears is the list generated by the previous Broadcast Search. Select the IE-CS(T)-2TX-xRS232/485 to which you would like to map COM ports. 5.
  • Page 79 IE-CS(T)-2TX-xRS232/485 IP Serial LIB Under classical mode, the driver will not notify the user’s program that Tx is completed until all Tx data has been sent out from the IE-CS(T)-2TX-xRS232/485; this mode will cause lower throughput. If you want to ensure that all data is sent out before further processing, classical mode is recommended. Enable/Disable Tx/Rx FIFO.
  • Page 80 IE-CS(T)-2TX-xRS232/485 IP Serial LIB opens the port via API. 8. After setting the COM Mapping, remember to select Apply Change to save the information in the host system registry. The host computer will not have the ability to use the COM port until after Apply Change is selected.
  • Page 81: Off-Line Com Mapping

    IE-CS(T)-2TX-xRS232/485 IP Serial LIB Off-line COM Mapping 1. Add a target by inputting the IP address and selecting the Model Name without physically connecting the IE-CS(T)-2TX-xRS232/485 to the network. 2. Modify the port settings as needed. 3. Right click in the IE-CS(T)-2TX-xRS232/485 list section and select Apply Change. COM Grouping The “COM Grouping”...
  • Page 82 IE-CS(T)-2TX-xRS232/485 IP Serial LIB COM Settings. 2. Select a COM number for this COM group. You may select one of the ports already assigned to a member of the COM Group. However, once the COM Group is configured, all of the original COM number(s) within the group will be released simultaneously.
  • Page 83 IE-CS(T)-2TX-xRS232/485 IP Serial LIB 3. Select the Grouping selected port(s) together checkbox. 4. On the COM Grouping page, you can set “Read” and “Write” permissions for every serial port. It is necessary to set Signal Status in order to control the data transmission with specified control signals (e.g., DTR/RTS).
  • Page 84: Deleting A Com Group

    IE-CS(T)-2TX-xRS232/485 IP Serial LIB to and removed from the Group. Click Apply to apply the settings. 6. Finally, click Yes to confirm. Deleting a COM Group Follow the steps below to delete a COM Group and then auto-assign COM numbers for each port in the Group: 1.
  • Page 85 IE-CS(T)-2TX-xRS232/485 IP Serial LIB 2. Select a COM number for this COM group and check the Auto enumerating COM number for selected ports to use the COM number you select as the first starting COM number, and then click OK. 3.
  • Page 86: Adding A Port To A Com Group

    IE-CS(T)-2TX-xRS232/485 IP Serial LIB Adding a Port to a COM Group Follow the steps below to add a serial port into an existing COM Group: 1. Select the serial port that you are adding and right-click to select COM Settings. 2.
  • Page 87: Removing A Port From A Com Group

    IE-CS(T)-2TX-xRS232/485 IP Serial LIB 4. Finally, click Yes to confirm. Removing a Port from a COM Group Follow the steps below to remove a serial port from a COM Group: 1. Select a serial port in the Group and right-click to select COM Settings. 2.
  • Page 88: Modify Ports In A Com Group

    IE-CS(T)-2TX-xRS232/485 IP Serial LIB 3. You will be able to view the serial ports that were assigned to and removed from the Group. Click Apply to apply the settings. 4. Finally, click Yes to confirm. Modify Ports in a COM Group In the following subsections we examine three ways in which the serial ports in a COM Group can be modified: Changing the COM Number of a COM Group 1.
  • Page 89 IE-CS(T)-2TX-xRS232/485 IP Serial LIB 2. Select a COM number that is not in use or assigned to a Group. 3. Select the Grouping selected port(s) together checkbox and then click OK. 4. You will be able to view the serial ports that were assigned to and removed from the Group. Click Apply to apply the settings.
  • Page 90: Changing Advanced Settings And Serial Parameters Of The Com Group

    IE-CS(T)-2TX-xRS232/485 IP Serial LIB 5. Finally, click Yes to confirm. Changing Advanced Settings and Serial Parameters of the COM Group 1. Check the port specified on the COM Grouping page as the signal port. 2. Select the ”Signal Status” controlled port and then right-click and select COM Settings. 6-27...
  • Page 91 IE-CS(T)-2TX-xRS232/485 IP Serial LIB 3. The Advanced Settings and Serial Parameters pages will be available for modification. 6-28...
  • Page 92: Changing The Serial Port Specified As Signal Port For The Com Group

    IE-CS(T)-2TX-xRS232/485 IP Serial LIB Changing the Serial Port Specified as Signal Port for the COM Group 1. Selecta serial port in the Group and then right-click and select COM Settings. 2. Check the Grouping selected port(s) together check box. 6-29...
  • Page 93: Ip Address Report

    IE-CS(T)-2TX-xRS232/485 IP Serial LIB 3. On COM Grouping page, you can specify one serial port whose signals will be taken into account by the COM Group and change the Read/Write status for each serial port. IP Address Report When IE-CS(T)-2TX-xRS232/485 is used in a dynamic IP environment, users must spend more time with IP management tasks.
  • Page 94 IE-CS(T)-2TX-xRS232/485 IP Serial LIB 3. Configure the Local Listen Port to be the same as the IE-CS(T)-2TX-xRS232/485’s “Auto report to UDP port” setting. 4. Click Go to start receiving the Auto IP address report from the IE-CS(T)-2TX-xRS232/485. 6-31...
  • Page 95: Pinouts And Cable Wiring

    Pinouts and Cable Wiring The following topics are covered in this appendix:  Port Pinout Diagrams  Ethernet Port Pinouts  RS-232/422/485 (male DB9) Pinouts  RS-422/485 (5-contact terminal block) Pinouts for the IE-CS(T)-2TX-1RS232/485  Power Input and Relay Output Pinouts ...
  • Page 96: Port Pinout Diagrams

    IE-CS(T)-2TX-xRS232/485 Pinouts and Cable Wiring Port Pinout Diagrams Ethernet Port Pinouts Signal RS-232/422/485 (male DB9) Pinouts RS-232 RS-422, 4-wire 2-wire RS-485 RS-485 TxD-(A) – 1 2 3 4 5 TxD+(B) – RxD+(B) Data+(B) RxD-(A) Data-(A) 6 7 8 9 – –...
  • Page 97: Serial Cable Wiring Diagrams

    IE-CS(T)-2TX-xRS232/485 Pinouts and Cable Wiring Serial Cable Wiring Diagrams Female DB9 to Male DB9 IE-CS Female DB9 to Male DB25 IE-CS...
  • Page 98: Ethernet Cables

    IE-CS(T)-2TX-xRS232/485 Pinouts and Cable Wiring Ethernet Cables...
  • Page 99: Well Known Port Numbers

    Well Known Port Numbers In this appendix, which is included for your reference, we provide a list of Well Known port numbers that may cause network problems if you set the IE-CS(T)-2TX-xRS232/485 to one of these ports. Refer to RFC 1700 for Well Known port numbers, or refer to the following introduction from the IANA.
  • Page 100 IE-CS(T)-2TX-xRS232/485 Well Known Port Numbers UDP Socket Application Service reserved Management Utility Echo Discard Active Users (systat) Daytime Any private printer server Resource Location Protocol Host name server (names server) Whois (nickname) (Login Host Protocol) (Login) Domain Name Server (domain) Trivial Transfer Protocol (TETP) Gopler Protocol Finger Protocol...
  • Page 101: Snmp Agents With Mib Ii & Rs-232 Like Groups

    SNMP Agents with MIB II & RS-232 Like Groups The IE-CS(T)-2TX-xRS232/485 has SNMP (Simple Network Management Protocol) agent software built in. It supports SNMP Trap, RFC1317 RS-232 like groups and RFC 1213 MIB-II. The following table lists the standard MIB-II group, as well as the variable implementation for the IE-CS(T)-2TX-xRS232/485. RFC1213 MIB-II Supported SNMP Variables System MIB Interfaces MIB...
  • Page 102 IE-CS(T)-2TX-xRS232/485 SNMP Agents with MIB II & RS-232 Like Groups UDP MIB TCP MIB SNMP MIB UdpInDatagrams tcpRtoAlgorithm snmpInPkts UdpNoPorts tcpRtoMin snmpOutPkts UdpInErrors tcpRtoMax snmpInBadVersions UdpOutDatagrams tcpMaxConn snmpInBadCommunityNames UdpLocalAddress tcpActiveOpens snmpInASNParseErrs UdpLocalPort tcpPassiveOpens snmpInTooBigs tcpAttempFails snmpInNoSuchNames Address Translation MIB tcpEstabResets snmpInBadValues AtIfIndex tcpCurrEstab...
  • Page 103: Rfc1317: Rs-232 Mib Objects

    IE-CS(T)-2TX-xRS232/485 SNMP Agents with MIB II & RS-232 Like Groups RFC1317: RS-232 MIB Objects Generic RS-232-like Group RS-232-like General Port Table RS-232-like Asynchronous Port Group rs232Number rs232PortTable rs232AsyncPortTable rs232PortEntry rs232AsyncPortEntry rs232PortIndex rs232AsyncPortIndex rs232PortType rs232AsyncPortBits rs232PortInSigNumber rs232AsyncPortStopBits rs232PortOutSigNumber rs232AsyncPortParity rs232PortInSpeed rs232PortOutSpeed The Input Signal Table The Output Signal Table rs232InSigTable...
  • Page 104: Auto Ip Report Protocol

    Auto IP Report Protocol IE-CS(T)-2TX-xRS232/485s provide several ways to configure Ethernet IP addresses. One of them is DHCP Client. When you set up the IE-CS(T)-2TX-xRS232/485 to use DHCP Client to configure Ethernet IP addresses, it will automatically send a DHCP request over the Ethernet to find the DHCP Server. And then the DHCP Server will send an available IP address to the IE-CS(T)-2TX-xRS232/485.
  • Page 105: Compliance Notice

    Compliance Notice CE Warning This is a Class A product. In a domestic environment, this product may cause radio interference in which case the user may be required to take appropriate measures. Federal Communications Commission Statement FCC - This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.