Udp Mode - Weidmuller IE-CS-2TX-1RS232/485 User Manual

Industrial serial to ethernet converter
Hide thumbs Also See for IE-CS-2TX-1RS232/485:
Table of Contents

Advertisement

IE-CS(T)-2TX-xRS232/485

UDP Mode

Packing length
Setting
0 to 1024
Default = 0, The Delimiter Process will be followed, regardless of the length of the data packet. If the data
length (in bytes) matches the configured value, the data will be forced out. The data length can be configured
for 0 to 1024 bytes. Set to 0 if you do not need to limit the length.
Delimiter 1
Setting
00 to FF
Delimiter 2
Setting
00 to FF
Once the IE-CS(T)-2TX-xRS232/485 receives both delimiters through its serial port, it immediately packs all
data currently in its buffer and sends it out the IE-CS(T)-2TX-xRS232/485's Ethernet port.
ATTENTION
Delimiter 2 is optional. If left blank, then Delimiter 1 alone trips clearing of the buffer. If the size of the serial
data received is greater than 1 KB, the IE-CS(T)-2TX-xRS232/485 will automatically pack the data and send
it to the Ethernet. However, to use the delimiter function, you must at least enable Delimiter 1. If Delimiter
1 is left blank and Delimiter 2 is enabled, the delimiter function will not work properly.
Delimiter process
Setting
Do Nothing,
Delimiter + 1,
Delimiter + 2,
Strip Delimiter
Delimiter + 1 or Delimiter + 2: The data will be transmitted when an additional byte (for Delimiter +1), or
an additional 2 bytes (for Delimiter +2) of data is received after receiving the Delimiter.
Factory Default
0
Factory Default
None
Factory Default
None
Factory Default
Do Nothing
5-23
Web Console Configuration
Necessity
Optional
Necessity
Optional
Necessity
Optional
Necessity
Optional

Advertisement

Table of Contents
loading

Table of Contents