Computer Control And Monitoring; Ethernet Upgrade Kit 15H885; E-Flo Plus Software Update - Graco 15J753 Instructions Manual

Variable frequency drive, motor drive control for graco e-flo plus electric circulation pumps
Table of Contents

Advertisement

Computer Control and
Monitoring
To control or monitor the system using the supplied soft-
ware with a computer (PC), the following components
are required:
Graco VFD, Part No. 15J753 or 15J754

Ethernet Upgrade Kit 15H885

Category 5 Ethernet Cable
To control the pump using a computer, the system must
be in remote mode and the SECURE/DISABLE switch
must be disabled.
To monitor the pump from a computer, the system must
be in local mode.
Ethernet Upgrade Kit 15H885
The Ethernet Upgrade Kit includes a module which
allows a computer to monitor/communicate with the
VFD via Ethernet. See manual 311612 for installation
instructions.
E-Flo Plus Software
Update
The following components are required to update E-Flo
Plus software:
PC
Control Techniques Communication Cable
(PC-to-drive Communications Cable, RS232/RS485
converter with 9-pin D-shell and RJ45 connectors)
Control Techniques CTNetAPI Installer
Control Techniques WinFlash
Installation Instructions
1. Connect to Emerson website
sonct.com).
24
(www.emer-
2. Go to Support/Downloads and select Software.
3. Register as a user to gain access to the Software
downloads.
4. Select Software.
5. Choose Unidrive SP option.
6. Download CTNetAPI Installer. Unzip and install the
program.
7. Create a folder for the WinFlash program.
8. Download and save WinFlash zip file into the folder.
9. Extract winflash.exe from the zip file.
Software update instructions
1. Launch winflash.exe.
2. Read information in the Introduction window and
select Next.
3. Choose Download a Compiled Program option and
select Next.
4. Browse for a Graco software file and select Next.
See F
. 6.
IG
F
. 6
IG

Computer Control and Monitoring

311596A

Advertisement

Table of Contents
loading

This manual is also suitable for:

15j754

Table of Contents