PNP Output
Model
Operation
mode
E2C-EDA41
NO (Normally
open)
E2C-EDA8
NC (Normally
closed)
E2C-EDA51
NO (Normally
open)
E2C-EDA9
NC (Normally
closed)
Note 1. Setting Areas for Twin-output Models
Normally open: ON between the thresholds for Channel 1 and Channel 2
Normally closed: OFF between the thresholds for Channel 1 and Channel 2
2. Timing Charts for Timer Settings (T: Set Time)
ON delay
Yes
Sensing
object
No
T
ON
NO
OFF
T
ON
NC
OFF
Nomenclature
Amplifier Units
Twin-output Models
(E2C-EDA11/EDA41/EDA6/EDA8)
Sub-Display (Green)
Main Display (Red)
Displays the threshold values
Displays the incident light level
and function settings.
or the function name.
Operation Indicator
Operation Indicator
for Channel 1 (Orange)
for Channel 2 (Orange)
ON when output is ON.
ON when output is ON.
OFF when output is OFF.
OFF when output is OFF.
E2C-EDA

Timing chart

Mode
selector
NO
Yes
Sensing
object
No
Operation
Lit
indicator
Not lit
(orange)
ON
Output
transistor
OFF
Load
Operate
(relay,etc.)
Reset
(Between blue and black lines)
Yes
NC
Sensing
object
No
Operation
Lit
indicator
Not lit
(orange)
ON
Output
transistor
OFF
Operate
Load
(relay,etc.)
Reset
(Between blue and black lines)
NO
Yes
Sensing
object
No
Operation
Lit
indicator
Not lit
(orange)
ON
Output
transistor
OFF
Load
Operate
(relay,etc.)
Reset
(Between blue and black lines)
Yes
NC
Sensing
object
No
Operation
Lit
indicator
Not lit
(orange)
ON
Output
transistor
OFF
Load
Operate
(relay,etc.)
Reset
(Between blue and black lines)
OFF delay
Yes
Sensing
object
No
T
ON
NO
OFF
T
ON
NC
OFF
Operation Keys
Function setting operations
UP
DOWN
MODE
Channel Selector
Used to select the channel to
display or set.
SET/RUN Mode Selector
Used to select SET or RUN mode.
Output circuit
Operation indicator
Operation indicator
(orange) ch1
(orange) ch2
Display
Proximity
Sensor
main
circuits
Fine positioning
indicator
Operation
(orange)
indicator (orange)
Display
Proximity
Sensor
main
circuits
One shot
Yes
Sensing
No
object
T
ON
NO
OFF
T
ON
NC
OFF
External-input Models
(E2C-EDA21/EDA51/EDA7/EDA9)
Sub-Display (Green)
Main Display (Red)
Displays the incident light level
Displays the threshold values
or the function name.
and function settings.
Operation Indicator
Fine Positioning Indicator
(Orange)
(Orange)
ON when output is ON.
Fine positioning setting
OFF when output is OFF.
Brown
Control
output ch1
12 to 24
Black
VDC
Control
output ch2
Load
Orange
Load
Blue
Brown
External
input
Orange
Control output
12 to 24
Black
VDC
Load
Blue
Operation Keys
Function setting operations
UP
DOWN
MODE
Operating Mode Selector
Used to select normally open
or normally closed.
SET/RUN Mode Selector
Used to select SET or RUN mode.
D-91

Advertisement

Table of Contents
loading

Table of Contents