4. Secure the small PC board and plastic standoff with two [2] screws. Note the standoff
mounts on the right side.
5. Route the audio cable to the connector on the AVS Base Unit and connect the cable.
TB 1
1
2
3
4
5
6
7
8
9
10
11
6. Ensure the audio cable ends are secured with tie wraps to reduce strain.

Wiring for ECP, 4204 and Two-4204 Modes

Most Honeywell ADEMCO control panels support LRR-ECP data communication, (e.g.,
VISTA-10P, VISTA-15P, VISTA-20P, VISTA-128BP and VISTA-128FBP). However, there
are some panels that do not. Check the Installation and Setup Guide for the control panel
you are using to see if it supports ECP communication.
Connect the IGSMV to a compatible Honeywell VISTA control panel's ECP terminals, in
parallel with keypads and other peripheral devices such as RF receiver, VIP module, etc.
Wire length/gauge limitations are the same for the module as they are for keypads and other
peripheral devices. To wire the module for ECP or 4204 modes, see Figure 2-2 and make the
following connections:
VISTA CONTROL PANEL
Figure 2-2. Wiring a VISTA for ECP Mode or 4204 Modes
FOR EXTERNAL ANTENNA
50 OHM, MMCX ONLY
7720P PROGRAMMER PORT
NOT FOR TELEPHONE SERVICE USE!
TRANSMIT LED
PRIMARY POWER:
BATTERY: 6V. 3.1 AHr FOR 24 Hr BACKUP
FCC ID: GIPMC56
IC: Y267W - MC56
MAC LABEL HERE
Honeywell
RED
+12V AUX
BLK
GND
YEL
DATA OUT
GRN
DATA IN
AVS BASE UNIT
ON
ON
1
2
3
4
1
2
3
4
5
TRANSFORMER
TB1
1
AC INPUT 1
AC INPUT 2
2
ECP (+) VOLTAGE INPUT
3
GND
4
5
ECP DATA IN
ECP DATA OUT
6
COMMUNICATIONS
MODULE
Section 2: Mounting and Wiring