Honeywell AlarmNet IGSMV Installation And Setup Manual page 37

Internet communication module
Table of Contents

Advertisement

PROMPTS
Telco Zone
31
(0)_
Open/Close Zone
32
(0)_
33
Zn1 Trigger Type
(V+)_
Restore Zn1 Y/N
34
(Y)_
Delay Zn1 (secs)
35
(00)_
Rpt Zn1 ONLY if
36
Armed (N)_
4204/
ZONE
ENTRY
TRIG.
2-4204
Section 3: Programming the IGSMV
OPTIONS
See Important Information Regarding Zone
Zone Trig:
Input Options on previous page.
[3-7]
Enter the zone number to be used for Telco
4204: [1-4]
line fault reports. This zone assignment must
be unique from the open/close zone selected in
2-4204: [1-8]
Prompt 32.
[0] = not used
Zone Trigger Mode: If any zone is
programmed for "report only if armed,"
zone 7 cannot be used. If Lynx Panic is
enabled, zone 3 cannot be used.
4204 Mode: If any zone is programmed for
"report only if armed," zone 4 cannot be
used.
2-4204 Mode: If any zone is programmed for
"report only if armed," or if tamper is
enabled, zone 8 cannot be used.
NOTE: Connect the Telco line fault output (or
relay output programmed for "Telco line
fault") to the Telco zone.
Enter the zone number to be used for
Zone Trig:
open/close (arm/disarm) reports.
[3-7]
This zone assignment must be unique from
4204: [1-4]
the Telco zone selected in Prompt 31.
2-4204: [1-8]
Zone Trigger Mode: If any zone is
programmed for "report only if armed,"
[0] = not used
zone 7 cannot be used as an open/close
zone. If Lynx Panic is enabled, zone 3
cannot be used.
4204 Mode: If any zone is programmed for
"report only if armed," zone 4 cannot be
used as an open/close zone.
2-4204 Mode: If any zone is programmed for
"report only if armed," or if tamper is
enabled, zone 8 cannot be used as an
open/close zone.
NOTE: Connect an open/close (arm/disarm)
trigger (or relay output) from the control
panel to the open/close zone.
 (V+)
Selects the triggering method for this zone
 (V–)
input.
 (EOLR)
Press the [space] key to scroll through
choices.
UL: V+ must be set as inverted and V– as
non-inverted.
[Y], [N]
Enables restore reporting for zone 1.
UL/ULC: Must be set to "Y."
[01-15]
Defines the reporting delay in seconds for
zone 1.
[00] = no delay
UL/ULC: Must be set to "00."
[Y], [N]
Report alarms on zone 1 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; or zone 8 in 2-4204
mode) is triggered (armed).
If [N], always reports alarms on zone 1.
DESCRIPTION
3-17