ECP Status Codes

When the IGSMV is configured for ECP mode, it sends status messages to the control panels
for battery, power, tamper, and network connectivity failures. Some of the control panels
(e.g., VISTA-10P, VISTA-15P and VISTA-20P Series) display these on the keypad as
"LngRng Radio" followed by a 4-digit code (listed in the table below). In addition, the
Contact ID codes (listed in Appendix B) for these conditions are sent to the central station by
the module.
The information in the following table is based on the VISTA-20 which has not been evaluated
UL
with this communication module.
STATUS CODE
0000
0880
4005
000F
0019
0400
0C80
0C8F
08E0
3000
8000
0060
ENTRY
OPTIONS
[Y] = review
[N] = exit
Table 3-3. Common ECP Keypad Display Status Codes
Control panel lost communication with IGSMV.
IGSMV tamper detected (cover removed).
IGSMV has lost contact with AlarmNet.
IGSMV is not registered; account not activated.
IGSMV shutdown.
IGSMV power on / reset AND the control panel lost communications with IGSMV.
IGSMV power on / reset AND tamper detected.
IGSMV power on/ reset AND tamper detected AND not registered.
IGSMV tamper detected and IGSMV battery low.
Primary power loss (will only be displayed in conjunction with another event).
Battery charger failure (will only be displayed in conjunction with another event).
Low battery (will only be displayed in conjunction with another event).
Section 3: Programming the IGSMV
DESCRIPTION
mary Comm Path Failure message will be delivered
after the programmed fault time expires.
If "Auto Detect" is chosen, the device will always try to
use IP to communicate but it will not generate a
Primary Comm Path Failure unless it previously
detected the presence of IP. As soon as the presence of
IP is detected, a Primary Comm Path Restore message
is generated and the value of IP Connectivity pro-
gramming parameter is changed from "Auto Detect" to
"Detected".
From this point on, the software expects connectivity.
The auto detect logic will resume only when the
parameter is changed back to "Auto Detect".
Reviewing Programming Mode Entries
To review the programming options (to ensure that
the correct entries have been made), press [Y]. The
programming prompts are displayed again. Use the
up/down arrow keys to scroll through the program
fields without changing any of the values. If a value
requires change, simply type in the correct value.
When the last field is displayed, the "REVIEW?"
prompt again appears.
To exit the programming mode, press [N] in
response to the "REVIEW?" prompt, and refer to
Exiting Programming Mode at the end of this section.
DESCRIPTION
3-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Alarmnet igsmvcn

Table of Contents