Remove The Gun; From The Sds Meter - Nordson Auto-Flo RT Gun Customer Product Manual

Table of Contents

Advertisement

Remove the Gun

from the SDS Meter

1. See Figure 4. Disconnect and lockout power to the
SDS Meter (1).
2. Turn off the supply air to the SDS Meter (1). Relieve
all fluid and air pressures.
3. Disconnect the gun cable (13) from the bulk
unloader controller.
4. Only perform this step if using the Auto-Flo RT gun
with a QUISS RTVision sensor head (5):
a. Disconnect the QUISS RTVision system
cables (4) from the sensor head (5).
b. Remove the screws (7) and lock washers (6)
securing the QUISS RTVision sensor head (5) to
the Auto-Flo RT gun (3).
10
8
Figure 4
Removing the Gun from an SDS Meter
E 2008 Nordson Corporation
11
13
12
9
5. Disconnect the air lines (10, 11) from the
fittings (9, 12).
6. Remove the screws (8) securing the Auto-Flo RT
gun (3) to the SDS meter (1). Remove the O-ring (2)
from the gun (3). Discard the O-ring.
2
3
4
5
Auto-Flo RT Gun
1
6
7
Part 1074874A--02
7