Initial steps using the ACLI
aging-time day <1-365>
default-lockout-time <60-65000>
lockout <word> time <time>
min-passwd-len <10-20>
password-history <3-32>
70
Commissioning
Variable
Value
• layer3 <word>
• oper
• read-only <word>
• read-write <word>
• read-write-all <word>
• slbadmin
• slboper
• ssladmin
<word> represents the new password with
0–20 characters.
Configures the expiration period for
passwords in days, from 1–365.
Changes the default lockout time after three
invalid attempts. Configures the lockout time,
in seconds, and is in the 60–65000 range.
The default is 60 seconds.
To configure this option to the default value,
use the default operator with the command.
Configures the host lockout time.
• word is the host IP address in the format
a.b.c.d.
• time is the lockout-out time, in seconds, in
the 60–65000 range. The default is 60
seconds.
Configures the minimum length for
passwords in high-secure mode.
To configure this option to the default value,
use the default operator with the command.
Specifies the number of previous passwords
the switch stores. You cannot reuse a
password that is stored in the password
history. The default is 3.
To configure this option to the default value,
use the default operator with the command.