Diagnostics Connector - VESPA GTS Super 125 i.e. Service Station Manual

Table of Contents

Advertisement

Electrical system
h - Disconnect the clamps from the battery and
check the voltage, if voltages are detected of less
than 12.8 V, proceed with a new recharge of the
battery starting from point c of the recharge pro-
cedure of the new battery, otherwise go to point i
i - The battery is now completely activated, disconnect the battery charger from the fuel supply grid,
disconnect the clamps from the battery and proceed to fitting the battery on the vehicle.
Connectors

DIAGNOSTICS CONNECTOR

1. Not connected
2. Ground lead (Black)
3. Electronic control unit (Violet - White)
PICKUP CONNECTOR
1. Control unit positive (Red)
2. Negative from control unit (Brown)
3. Not connected
FUEL PUMP CONNECTOR
1. Not connected
2. Ground lead (Black)
3. Not connected
4. Not connected
5.Power from relay (Black - Green)
ELE SYS - 98
Vespa GTS Super 125 i.e.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents