Technical Specification And Installation Requirements - Zenith HydroTap G4 Celsius Series Installation Instructions Manual

Filtered, boiling, chilled and chilled sparkling drinking water with unfiltered hot and cold ambient water, for commercial kitchens
Table of Contents

Advertisement

Cups of
Boiling
Model
Water per
Hour
B
160
C
NA
1. The Cup measurement =167ml and the Glass measurement = 200ml
Chilled water will continue to be dispensed after the rated capacity has been used, although this may be at
2.
slightly higher temperature.
Product covered by these instructions:
Capacity
Boiling
(cups)
Boiling Only
B160
160
B240
240
Chilled Only
C125
NA
C175
NA
Chilled Sparkling
CS175
NA
Before installing ensure the following are provided at the Installation site:
• Review all the technical specifications.
• Ensure the underbench can support the product weight when full of water
• Sufficient space in the cupboard to install all of the undersink units in accordance with these Installation
Instructions. Refer to technical specification for dimensions. Refer to section 3 & 4, for Installation
instructions.
• For all models, a 220-240Vac, 10A GPO will be required.
NOTE: Check all cable and hose lengths against inlet /outlet positions before
proceeding (See section 4 for general layout).
• A potable water supply connection with isolating valve inside the cupboard within reach of the braided
hoses and positioned so that the connection point and the stop cock will not be obstructed when the
undersink units are installed.
• If an external filtration or water softening device is required, then it is important to allow extra space for
these items.
• A cold water supply with a minimum working pressure of 172kPa (for B&C), 200kPa (with a Booster
and /or filter softener), 250kPa (for CS) and a maximum working pressure of 700kPa connected via an
isolation valve.
• The appliance must be placed with it's base in a horizontal position.
IMPORTANT!
Do not proceed with the Installation if these requirements are not met.
802700NZ - Commercial Installation Instructions - Aug 2015 - V2.01
Technical Specifications
Glasses
of Chilled
Commercial Models
Water per
Hour
B
C
NA
CS
125
Capacity
Boost
GPO's
Chilled
(10A)
Required
(glasses)
NA
no
NA
yes
125
no
175
no
175
no
Boiling + Mains Mixed water
Chilled + Mains Mixed water
Chilled Sparkling + Mains Mixed water
Power
Boost
Rating
Rating
(kW)
(kW)
1x10A
1.9
NA
2x10A
1.9
2.2
1x10A
0.175
NA
1x10A
0.300
NA
1x10A
0.450
NA
Unit Dimensions
Dry
W x D x H (mm)
Weight
with airduct
(Kg)
280 x 313 x 335
280 x 313 x 335
336 x 476 x 335
336 x 476 x 335
336 x 476 x 335
Page 9 of 32
8
8
20
20
26