3.2
Installation Procedure
Site requirements
• Appliance must only be installed in a frost-free area. Never expose appliance to frost.
• The Appliance is designed for wall mounted Installation and must to be installed with water connectors
facing upwards.
• The appliance complies with protection class IP 25.
• The 400mm braided hoses supplied with the unit cannot be lengthened.
• The 90° elbow hose ends, should be fitted to the inlet and outlet connections on top of the Booster.
• The hot water outlet hose must be thermally insulated with the insulation provided.
3.3
To Remove / Install the appliance
Insert a flat head screwdriver all the way into the lock.
1.
Gently angle the screwdriver upwards by approximately 10° as shown in the image below.
2.
Pull the appliance forwards by approximately 15° as shown.
3.
Carefully pull the appliance upwards to complete the removal process. Taking care not to break the
4.
lower clips
To install; Place the appliance on the wall bracket and snap into position (See installation below).
5.
Note: Remove the backing plate for wall mounting
Release
Page 18 of 32
Booster Installation
Tilt Forward
Installation
802700NZ - Commercial Installation Instructions - Aug 2015 - V2.01
Lift UP
Take care
not to break
the lower
clips when
removing or
installing the
Booster