Specification - Zenith HydroTap G4 Celsius Series Installation Instructions Manual

Filtered, boiling, chilled and chilled sparkling drinking water with unfiltered hot and cold ambient water, for commercial kitchens
Table of Contents

Advertisement

3.2
Installation Procedure
Site requirements
• Appliance must only be installed in a frost-free area. Never expose appliance to frost.
• The Appliance is designed for wall mounted Installation and must to be installed with water connectors
facing upwards.
• The appliance complies with protection class IP 25.
• The 400mm braided hoses supplied with the unit cannot be lengthened.
• The 90° elbow hose ends, should be fitted to the inlet and outlet connections on top of the Booster.
• The hot water outlet hose must be thermally insulated with the insulation provided.
3.3
To Remove / Install the appliance
Insert a flat head screwdriver all the way into the lock.
1.
Gently angle the screwdriver upwards by approximately 10° as shown in the image below.
2.
Pull the appliance forwards by approximately 15° as shown.
3.
Carefully pull the appliance upwards to complete the removal process. Taking care not to break the
4.
lower clips
To install; Place the appliance on the wall bracket and snap into position (See installation below).
5.
Note: Remove the backing plate for wall mounting
Release
Page 18 of 32
Booster Installation
Tilt Forward
Installation
802700NZ - Commercial Installation Instructions - Aug 2015 - V2.01