Trouble Shooting; Trouble Shooting Table; End Of Life Disposal - Zenith HydroTap G4 Celsius Series Installation Instructions Manual

Filtered, boiling, chilled and chilled sparkling drinking water with unfiltered hot and cold ambient water, for commercial kitchens
Table of Contents

Advertisement

System Fault
Message
Power board fault
Interface fault
Level board fault
Condenser screen blocked Blocked Air filter
Water leak, Isolate mains
Compressor over-run
Water supply failed
Hot sensor Open
Hot sensor Closed
Cold sensor Open
Cold sensor Closed
Flood sensor Open
Condenser sensor Closed
Condenser sensor Open
Heater fuse / driver fault
Heater driver fault
Compressor driver fault
Hot sensor degraded
Condenser overtemp.
A DC Pump is faulty
Steam is too cool
Steam sensor Open
Steam sensor Closed
Over Steamed
Hot tank overfilled
Comp Fuse/Driver Fault
Hot tank under filled
Boil dry protection
Flash Mem corrupted
Flow Sensor Fault
Call an electrician, a plumber, or Zenith on 0800 558055 for assistance, service, spare parts or enquiries.
In order to help preserve our environment we ask that you dispose of this product correctly. Please contact
your local city council for collection centre details.
802700NZ - Commercial Installation Instructions - Aug 2015 - V2.01

Trouble Shooting

Possible Cause
Electrical disruption
Internal fault
Internal fault
Water leak
Compressor too Hot
No water
Internal fault
Internal fault
Internal fault
Internal fault
Internal fault
Internal fault
Internal fault
Internal fault
No hot water
No chilled water
Internal fault
Blocked air filter
Internal fault
Internal fault
Internal fault
Internal fault
Internal fault
Internal fault
Internal fault
Low water pressure
Safety activated
Internal fault
Internal fault

End of Life Disposal

Solutions
Check power supply and all fuses
Call Zenith Service
Call Zenith Service
Remove blockage / Clean filter / check user guide
Turn off mains water supply / Call for service
Check ventilation
Check water supply is turned ON
Call Zenith Service
Call Zenith Service
Call Zenith Service
Call Zenith Service
Call Zenith Service
Check Ventilation / Call Zenith Service
Check ventilation / Call Zenith service
Call Zenith Service
Call Zenith Service
Call Zenith Service
Call Zenith Service
Remove blockage / Clean filter / check user guide
Call Zenith Service
Call Zenith Service
Call Zenith Service
Call Zenith Service
Call Zenith Service
Call Zenith Service
Call Zenith Service
Check water supply
Turn OFF / On power to reset
Call Zenith Service
Call Zenith Service