Section 3 - Booster - Zenith HydroTap G4 Celsius Series Installation Instructions Manual

Filtered, boiling, chilled and chilled sparkling drinking water with unfiltered hot and cold ambient water, for commercial kitchens
Table of Contents

Advertisement

Booster Heater
3.1
Product Description
The boost unit is a compact electronically
controlled auxiliary water heater. It is intended to
provide pre heating of water before it enters the
Zenith HydroTap G4 boiling tank. The Booster is
supplied as standard equipment with all 240 cup
models. However, it may be later installed, as an
accessory for the 160 cup models, to increase
their delivery to 240 cups.
Note 1: water connection
:Blue marking - water in
:Red marking - water out.
The braided hoses cannot be
lengthened.
Note 2: The electrical cable
length is 1.0 metre.
Note 3: Position the Booster
within reach of the fixed hose
lengths, keeping the Booster
as close as possible to the
undersink unit inlet/ outlet
fittings.
Note 4: Ensure the Booster
heater is mounted in an
upright position (as shown)
with a horizontal base
Booster Specifications:
Nominal Power Rating
Nominal Current
Electric Supply
Elect fl ex and plug (black) - 1 meter length (with 90º Australian plug)
Fixed Flow Rate
Minimum inlet pressure
802700NZ - Commercial Installation Instructions - Aug 2015 - V2.01
Section 3
50Hz AC
(B240)
280mm
Mount base
Horizontally
Rating
Unit
2.2
kW
10
A
230
V
10
A
1.2
L/min
200
kPa
Page 17 of 32