Note 1: This appliance is intended for use with the Zenith HydroTap under sink
unit.
Note 2: Water connections must be pointing vertically upwards.
Note 3: The booster unit should be installed as close as possible to the Zenith
HydroTap Unit as the 400mm connection hoses cannot be lengthened.
3.4
Braided hose connections
The cold water inlet (blue) and hot water outlet (red) are marked on the rating plate. Connect the
1.
braided hoses from the 'Bypass Out' fitting on the Zenith HydroTap, to the water inlet of the booster
unit (Marked Blue) and from the outlet of the booster unit (Marked Red) to the 'Bypass IN' fitting on the
Zenith HydroTap unit. Avoid exerting any mechanical pressure on the appliance. This can be achieved
by applying a spanner on the flats of the inlet and outlet connections when tightening the braided hose
connectors. Do not overtighten ! Tighten the braided hoses by hand, then turn an additional 90° - 180°
with a spanner
Once the water connections have been made, check for any leaks and rectify as necessary.
2.
Typical Installation
Braided Hoses
Strainer
Cold Water
Connection
(inlet, G1/2")
Hot Water
Connection
(outlet, G1/2")
802700NZ - Commercial Installation Instructions - Aug 2015 - V2.01
Booster System
Hold the hexagon while
tightening the braided
hose fittings
Page 19 of 32