Undersink Unit Installation
6.1
Hose fitting
Install the mains water braided hoses to the undersink unit before locating the unit in place.
Note:
The tube lengths are matched to the pumps performance and therefore CANNOT be lengthened
Note:
Insulate the Blue and White tubes after trimming to length
John Guest fittings
Be careful when cutting the poly tube so that there are no rough edges and that the tube is not distorted.
Use a sharp knife to ensure the tube has a clean,
1.
straight edge. Do not cut at an angle.
Remove any swarf or unwanted material.
2.
Push the tube into the John Guest fitting making
3.
sure all connections to the John Guest fittings are
pushed in past the "O"ring to full depth, at least
15-16mm.
Check for a good joint by pulling back on the tube.
4.
If the tube comes out, of the fitting, repeat the
above step.
To remove the tube, press the collet into the fitting
5.
and at the same time pull back on the tube.
6.2
Clearances
802700NZ - Commercial Installation Instructions - Aug 2015 - V2.01
Section 6
(Insertion and removal)
Common kitchen layout
392mm
Page 23 of 32