Product Specifications
Indoor Unit (cont.)
Slim 1way cassette type (cont.)
Model
Power Supply
1)
Mode*
Capacity
Performance
Condensate (with High fan speed)
Input
Power
Running Current
4)
Sound Level
Sound Pressure *
Type
Fan
Motor
Cooling (High)
Airflow Rate
Heating (High)
Type
Refrigerant
Control Method
Temperature Control
Safety Devices
Liquid (Flare)
Piping
Gas (Flare)
Connections
Drain (Quick Lock)
Net Weight
Weight
Shipping Weight
Net Dimensions (W x H x D)
Dimensions
Shipping Dimensions (W x H x D)
Model
Net Weight
Panel Size
Shipping Weight
Net Dimensions (W x H x D)
Shipping Dimensions (W x H x D)
Auto Restart
Auto Swing
Functions
Group/Individual Control
External Contact Control
Trouble Shooting by LED
Installation Manual
Operation Manual
Pattern Sheet for Installation
Standard
Accessories
Flexible Drain Hose
Filter / Safety Grille
Drain Pump (Pumping speed, lift)
Wireless Remote Controller
Optional
Wired Remote Controller
Accessories
External Contact Interface Module
*1) Mode
- HP : Heat Pump, HR : Heat Recovery
*2) Nominal cooling capacities are based on;
- Indoor temperature : 27˚C DB, 19˚C WB
- Outdoor temperature : 35˚C DB, 24˚C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m
*3) Nominal heating capacities are based on;
- Indoor temperature : 20˚C DB, 15˚C WB
- Outdoor temperature : 7˚C DB, 6˚C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m
*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
*5) Specifications may be subject to change without prior notice for product improvement.
4
ø/V/Hz
kW
2)
Cooling*
Btu/h
kW
3)
Heating*
Btu/h
Liters/h
W
A
dB(A)
-
Model
-
Type
-
Output
W
3
m
/min
3
m
/min
-
-
-
-
ø, mm
ø, mm
ø, mm
kg
kg
mm
mm
-
kg
kg
mm
mm
-
-
-
-
-
-
-
-
-
-
ℓ/h,mm
-
-
-
AM056 N1DEH
1/220~240/50
HP/HR
5.6
19,100
6.3
21,500
-
55.0
0.28
36
Crossflow Fan
SIC-55CVL-F158-3
FDA6531SSH
BLDC
54W
16.00/14.00/12.50
16.00/14.00/12.50
R410A
EEV
Micom & Thermistors
Fuse
6.35
12.7
VP20 (OD 26,ID 20)
14
18
1200 x 138 x 450
1435 x 224 x 525
PC1BWSMAN
6.3
8.3
1410 x 23 x 500
1474 x 122 x 566
O
O
O
O
O
O
X
O
O
Filter (Washable)
24, 750
MR-DH00
MWR-WE10N
MIM-B14
AM071 N1DEH
1/220~240/50
HP/HR
7.1
24,200
8.0
27,300
-
80.0
0.40
39
Crossflow Fan
SIC-55CVL-F158-3
FDA6531SSH
BLDC
54W
17.00/15.50/14.00
17.00/15.50/14.00
R410A
EEV
Micom & Thermistors
Fuse
9.52
15.88
VP20 (OD 26,ID 20)
14
18
1200 x 138 x 450
1435 x 224 x 525
PC1BWSMAN
6.3
8.3
1410 x 23 x 500
1474 x 122 x 566
O
O
O
O
O
O
X
O
O
Filter (Washable)
24, 750
MR-DH00
MWR-WE10N
MIM-B14
Samsung Electronics

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Am022hn1deh/euAm028fn1deh/euAm022fn1deh/euAm036fn1deh/euAm071jn1deh/euAm056fn2deh/eu ... Show all

Table of Contents