5-7 S-METER ADJUSTMENT (continued)
1) Select an adjustment item using [VFO/MHz] / [M/CALL].
2) Set the SSG as specifi ed (frequency and output level).
3) Push [BAND] to adjust (automatic) and store the adjustment value.
ADJUSTMENT
ADJUSTMENT
(Full scale)
[UHF band 3] (FM)
(Full scale)
[UHF band 3] (FMN)
†
; This output level of a standard signal generator (SSG) is indicated as SSG's open circuit.
5-8 SQUELCH ADJUSTMENT
1) Select an adjustment item using [VFO/MHz] / [M/CALL].
2) Push [BAND] to adjust (automatic) and store the adjustment value.
ADJUSTMENT
ADJUSTMENT
SQUELCH
[VHF band 1] (FM)
[VHF band 1] (FMN)
[VHF band 2] (FM)
[VHF band 2] (FMN)
[UHF band 1] (FM)
[UHF band 1] (FMN)
[UHF band 2] (FM)
[UHF band 2] (FMN)
[UHF band 3] (FM)
[UHF band 3] (FMN)
ITEM
20 • Set the SSG as;
[SF5]
Frequency
Level
21 • Set the SSG as;
[SF5]
Frequency
Level
ITEM
1 • Connect a terminator to the antenna connector.
[SQ1]
[SQ1]
2
[SQ2]
3
[SQ2]
4
[SQ3]
5
[SQ3]
6
[SQ4]
7
[SQ4]
8
[SQ5]
9
[SQ5]
10
OPERATION
: (Displayed on the function display)
†
: +12 dBµ (–95 dBm)
: (Displayed on the function display)
†
: +12 dBµ (–95 dBm)
OPERATION
5 - 9
VALUE
Push [BAND].
(Automatic
adjustment)
VALUE
Push [BAND].
(Automatic
adjustment)
Need help?