Pump Electrics Check; Connectors; Pump Supply; Fuel Pump Connector - PIAGGIO XEVO 125 Euro 3 Service Station Manual

Table of Contents

Advertisement

XEVO 125 Euro 3
Note: With the battery charger drw. 020334Y, it is possible to check the battery charge level with the
Check function. The value indicated on the display must be higher than the value indicated on the chart;
otherwise, recharge the battery again in the same way indicated above.

Pump electrics check

Connect the tester positive probe to pin 4 of the
connector of the fuel pump control device, and the
negative probe to pin 3, making sure there is bat-
tery voltage as indicated in the table.
Specification
Key set to «KEY ON»
Engine revs from 0 to 200 rpm
Engine revs from 200 to 1200 rpm
Engine revs from 1200 to 2000 rpm
Engine rpm ] 2000 r.p.m.

Connectors

FUEL PUMP CONNECTOR

1. Ground (White-Black)
2. Live supply (Blue-Black)

PUMP SUPPLY

Supply to the pump for 13 seconds
Electrical system
Desc./Quantity
Always «OFF»
Always «ON»
0.2 seconds «ON»
9 seconds «OFF»
Always «ON»
ELE SYS - 25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents