XEVO 125 Euro 3
System bleed calliper fitting: 12 ÷ 16 Nm
Front
- Remove the rubber hood from the bleed screw.
- Insert a rubber pipe in the bleed screw to permit
the brake fluid to be recovered.
- With the brake lever, load the system and bring
it up to the required pressure.
- Keeping the brake lever pulled, loosen the bleed
screw to purge the air in the system. Then tighten
the bleed screw
- Repeat the operation until only brake fluid comes out of the rubber pipe.
- Remove the fluid recovery pipe and refit the rubber cap over the bleed screw.
- Top up the brake fluid to the right level in the reservoir.
If necessary, bleeding can be done using a special vacuum pump
N.B.
DURING THE BLEEDING OPERATIONS, MAKE SURE THE BRAKE FLUID DOES NOT COME INTO
CONTACT WITH THE BODYWORK SO AS NOT TO DAMAGE IT. FURTHERMORE, DURING THE
BLEEDING OPERATIONS REGARDING THE BRAKE CALLIPERS, MAKE SURE THE BRAKE
FLUID DOES NOT COME INTO CONTACT WITH THE DISC BRAKES AND WITH THE BRAKE
PADS. FAILURE TO COMPLY WITH THIS NORM WILL ENDANGER THE PROPER WORKING AND
EFFICIENCY OF THE BRAKING SYSTEM
Specific tooling
020329Y MityVac vacuum-operated pump
Locking torques (N*m)
System bleed calliper fitting: 12 ÷ 16 Nm

Brake fluid level check

- Position the vehicle on a flat surface and on the
centre stand
- Remove the brake pump cover as indicated in the
photo
Braking system
BRAK SYS - 9