Specifications

Description
Detection Technique
Dimensions
Weight
Operating Temperature
Operating Humidity
Power input (from power adaptor/charger or direct-wired)
Power consumption
Manufacturer
Model
Input
Power adaptor/
Output
charger
CCN
Mark of conformity
Environmental use
Communications
Flow System
Local Alarms/Status
Interface
Data Logging
concrete
Mounting
screws
wood
Battery type
Battery life
Maximum inlet/outlet pressure differential
Communication connector, optional communications cable
Relays
Minimum
Wire gauges
Maximum
USB
Indoor/outdoor use?
Operating
-1,000 to 3,000 ft. above sea level
altitudes
above 3,000 ft. to 6,000 ft. above sea level
Ingress Protection rating
External switch or circuit breaker requirement (description & location)
Ventilation requirements
Inhibit
Maintenance
4-20 mA output
defaults and
Instrument fault
ranges
Over-scale
4-20 mA configurations
Detector
Storage
conditions
Chemcassette cartridges
Detector
Certifications
Battery
Self-declared European CE Mark on detector for:
Chemcassette-cartridge-based with advanced self monitoring optics design
see
"Dimensions" on page 28
9.1 lbs. (4.1 kg)
0C to 40C for most gases / applications
0-100% RH for detector (Sample RH limited per tape/calibration). Sample line requires additional hardware to remove moisture in
high RH conditions where condensing may occur. The sample must be non-condensing. Dry conditions may require humidification.
24 VDC ±10%, 3.75 amps
~1.9 A at 24 VDC ±10% (including battery-charging current)
CUI Inc.
SD190-24-U-ST
90~264 VAC, 1.2 A, 47-63 Hz
24 VDC, 3.75 A max
QQGQ (file #E210311)
UL listed
Indoor only
Relays: Alarm 1, Alarm 2, Fault (user configurable for normally open/closed)
4-20mA
Ethernet (with Modbus TCP/IP and web server)
USB port (for flash drive configuration/data transfer)
Automatic flow control with bypass system, 250 or 500 cc/min at tape, higher flow at inlet to reduce sample time (internal
bypass system); sample up to 100 ft
Visual: LEDs for alarm, normal condition and fault
Audible: User selectable: Off, Low ~75 dB at 1 m, Medium ~85 dB at 1 m, High >90 dB at 1 m
4 large buttons, 3.5" Color LCD TFT display, web server
Rolling 3 months (15 sec. with no gas reading, 1 sec. when reading gas), Event history (1500 events – approx. 1 year)
5/16 in x 2 in vibration-resistant stud anchor for concrete (McMaster-Carr 94475A185 or equivalent), add 0.25 in. to length
when mounting bracket with sun shield
5/16 in. x 2 in. flange head lag screw for wood (McMaster-Carr 95526A375 or equivalent), add 0.25 in. to length when
mounting bracket with sun shield
Lithium ion
Approximately 70% of original capacity after 300 full charge/discharge cycles; 6+ hours under typical operating conditions
The overall maximum load on the pump between the inlet and the exhaust should not exceed 10 inches H
60 V, 5 A maximum
250 V, 6 A maximum
20
14
2.0 or later
both (the power adaptor/charger is indoor only)
standard
requires factory adjustment, contact Honeywell Analytics
IP65
meet or exceed all local codes and regulations
mount with no obstructions within 4 in. (10 cm) of either side or within 2 in. (5 cm) above and below the detector
2 mA, programmable from 1.5-3.5 mA in 0.5 mA increments
3 mA, programmable from 1.5-3.5 in 0.5 increments
1 mA or less, not programmable (will be driven under 1 mA)
21.5 mA, programmable 21-22 mA
sink, source, isolated
32°F to 104°F (0°C to 40°C), 0-100% RH non-condensing
Refer to the label on the Chemcassette cartridge for storage conditions
UL 61010-1, 3rd Edition, 2012-05 (ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE -
Part 1: General Requirements
CAN/CSA-C22.2 No. 61010-1, 3rd Edition, 2012-05, (ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND
LABORATORY USE - Part 1: General Requirements)
IEC 61010-1:2010, 3rd Edition
Global radio transmission approvals
UL/cUL Recognition to UL 2054 + 60950-1
IEC 62133 1st Edition CB Certification
UN Test Report to UN 38.3
EMC, LVD, ROHS, WEEE
SPM Flex Gas Detector
Value
2
O
63