12
Specifications
Physical specification
Dimension
Weight
Power supply
DC input voltage (nominal)
AC input voltage (nominal)
Inrush current
Maximum power consumption
mA Versions
Modbus versions
Relay versions
Outputs
§
Analog output
Digital output
Relay output
Operating Environment
Operating temperature
Storage temperature
Humidity
Atmospheric pressure
Ingress protection
Installation category
Pollution degree
Cable Gland
Inner knock-out
Outer knock-out
Gas Test Tubing
Inner diameter
Outer diameter
mA versions: 11 to 32 VDC, Modbus versions: 9 to 32 VDC
20 to 27 VAC
Dependent on version
§
Flammable catalytic versions: 10 to 90% RH. Operating the detector outside of this range may result drift and a
decrease detector accuracy.
3017M5000_1 HAA170019
© 2017 Honeywell Analytics
113 mm × 113 mm × 59 mm (4.4 × 4.4 × 2.3 in)
500 g (1.1 lb)
24 V DC†
24 V AC‡, 50/60 Hz
Less than 850 mA
< 1.2 W (toxic), < 1.7 W (flammable)
< 0.7 W (toxic), < 1.2 W (flammable)
Additional 0.6 W
0 to 22 mA sink or source (configurable)
Modbus RTU
2 × dry contact relays for fault and alarm signalling. Rated at 5 A @ 24 V DC, 5 A @ 240 V AC
−20 to 50°C (−4 to 122 °F)
0 to 30°C (32 to 86 °F)
0 to 99% (non-condensing)
90 to 110 kPa
IP65 / Type 4 (in accordance with NEMA 250)
II (UL/CSA/IEC/EN 61010-1)
2 (UL/CSA/IEC/EN 61010-1)
M20 or ½ NPT
M25 or ¾ NPT
4 or 6 mm
6 or 8 mm
4
5