Autoresponse; Chassis Level Events And Responses - 3Com CommWorks 5210 User Manual

Ip telephony manager
Table of Contents

Advertisement

AutoResponse

Chassis Level Events
and Responses
The AutoResponse can be invoked by the following syntax:
tcmarsp [-E event] [-h] [target]
Where:
-E event
Specifies which event to use as the default.
The specified parameter must be a substring of one of the event descriptive
strings described below. Substrings that match at the beginning of the
descriptive string have precedence over those that match in the middle. When
there are embedded spaces in the substring, the event should be properly
quoted according to shell rules. The match is case insensitive.
If no event is specified, the GUI defaults to the entire list of AutoResponse
events.
The following are the events and the responses to the events from the
AutoResponse command
Events
PSU Voltage Out of Range
PSU Failed
Fan Failed
HUB Temperature Out of Range
Global Timer 1 Expired
Global Timer 2 Expired
Global Timer 3 Expired
Global Timer 4 Expired
Responses (the "(N)" notation indicates that the response requires a
parameter):
Generate AutoResponse SNMP Trap ID (N)
Delay Script Execution (N) Seconds
Terminate Script Execution
Continue If Test Passes
Configure Module From NMC NVRAM
Configure Module From NMC Factory Defaults
Test module
Reset module
AutoResponse 123

Advertisement

Table of Contents
loading

Table of Contents