8 SERVICE INSTRUCTIONS
9. Gate pulses from 20AP1.
Measure with the screen (gnd) connected to +24 V.
The pulse frequency must be 40 kHz ±1 kHz.
The pulse duration must be 41-44% of the cycle time, measured at -10 V of the
negative pulse, as shown in the graph below.
If there is an interruption in the connection to the pulse transformer, the pulses are
shaped as shown in the graph below
10. Gate pulses to the IGBTs.
Measure with the probe connected to the gate.
The pulse frequency must be 40 kHz ±1 kHz.
The pulse duration must be 40-44% of the cycle time, measured at +5 V, as shown
in the graph below.
0740 800 172
- 91 -