8 SERVICE INSTRUCTIONS
9. Gate pulses from 20AP1.
•
Measure with the screen (gnd) connected to +24 V.
•
The pulse frequency must be 40 kHz ±1 kHz.
•
The pulse duration must be 41-44% of the cycle time, measured at -10 V of the
negative pulse, as shown in the graph below.
•
If there is an interruption in the connection to the pulse transformer, the pulses are
shaped as shown in the graph below
10. Gate pulses to the IGBTs.
•
Measure with the probe connected to the gate.
•
The pulse frequency must be 40 kHz ±1 kHz.
•
The pulse duration must be 40-44% of the cycle time, measured at +5 V, as shown
in the graph below.