Finally, press

5.2 Counting parameters

CNT 01. Current counting
Range:0 — 999999
Unit:
Default:
CNT 02. Preset counting
Range:0 — 999999
Unit:
Default:
Notes:
1、 Increasing mode: When the value of CNT01(current counting)increase to the value of CNT02
(preset counting),counting arrives and port exports.
2、 Decreasing mode: When finishing setting parameter CNT02 (preset counting) ,the value of CNT01
(current counting)will be set the same value automatically. When the value of CNT01(current
counting)decrease to '0', counting arrives and port exports.
3、 When parameter CNT02(preset counting)is set as '0', E10 will count and not export any output
signals.
4、 If the parameter of port function for counting arrived is not set, then there will be no output.

5.3 Time relay parameters

DLY 01.
T1 time setting
Range:10 — 50000
Unit:ms
Default:1000
DLY 02.
T2 time setting
Range:10 — 50000
Unit:ms
Default:1000
DLY 03.
T3 time setting
Range:10 — 50000
Unit:ms
Default:1000

5.4 Teach in parameters

Teach-in parameters for press-braking machine
PAC 01. X-axis current position
Range:0 — 999999
Unit:Display Unit
Default :0
PAC 02. Y-axis current position
to exit Teach-in parameter edit interface.
Page 15 of 28
E10 Operation Manual V1.15
used to set time for relay 1
used to set time for relay 2
used to set time for relay 3
Display X-axis current position
Display Y-axis current position