Chapter 3
This chapter will be made available to you to install and the correct method of wiring. For the sake of
system security, and ensure that the machine be able to operate normally, you must read the user manual
carefully before the installation / wiring.

3.1 Installation and wiring Notes

In implementation of the installation, wiring, be sure to turn off the power (Example: the installation
of encoder).
Misuse power terminal access, improper connected input and output lines, the output line short circuits
cause the system is major injury. So check in before power on, it is necessary to check carefully the power
supply and the grounding wires, input and output lines are connected properly.
E10 Series systems' grounding terminal must be properly grounded. And so does as the shell.
Recommend the use of switching power supply.
Separate high voltage from low voltage in the electric cabinet by use of the metal hose, which is
connected to the earth.
Installation of inductive load such as electromagnetism valve and AC contactor must connect RC
absorber.
In order to avoid any failure, please do not take down the system privately,.
Electronic components of E10 system are all sensitive to static electricity. It will not be allowed to fall
into any foreign body insertion or touch the control circuit boards of E10 system.
Select the safety region to install E10 system, prevent heat and direct sunlight, avoid moisture and
splash water drop splash.
Do not use in surroundings which has heat, condensate water, dust, soot, conductive dust, corrosive
gases, flammable gases.

3.2 Installation direction and space

E10 Series systems are in general inlayed in the control panel, keep enough space with the adjacent
components and baffle (shell).

3.3 Installation surroundings

Free droplets, steam, dust and oily dust places.
No inflammable, explosive, corrosive gases.
No strong electromagnetic noise interference.
Make sure the ambient temperature is at 0 ℃ between 50 ℃. If the ambient temperature exceeds 40 ℃,
please make sure it is a well-ventilated place.
Make sure the relative humidity is below 90%.

3.4 Overall dimensions

E10 Series systems are in the same model dimensions. There are two methods: plastic shell
installation and panel installation.
Installation Method 1: plastic shell installation, refer to Appendix 2.
Installation Method 2: panel-type installation, refer to Appendix 3.
Installation and debugging