E10 Electrical Design Typical Application Example - Estun E10 Operation Manual

Numerical display system
Table of Contents

Advertisement

3.7 E10 electrical design typical application example

1
AC1
2
AC2
3
4
GND
+24V
+24V
Electrical Design Description:
The input access method:
1, has to find a reference point function:
Shearing machine : input IN1 (normally open signal) as the shear count signal input, then input IN2
accesses reference point.
Bending machine: input IN1 and IN2 access the reference point.
2, there is no function to find a reference point:
1, has soft-limit function:
Shearing machine : input IN1 (normally open signal) as the shear count signal input, an external
relay. IN2 may not access.
Bending machine: input IN1, and IN2 not access.
2, there is no soft limit function:
Shearing machine: input IN1 (normally open signal) as the shear count signal input, an external
relay. Input IN2 as a time relay input.
Bending machine: with the Shearing machine, input IN1, IN2 (normally closed) as a time relay
input, the signal mode is optional.
Note: input IN1 (normally open signal) as a count signal input, an external relay. Input IN1, IN2 (normally
closed) as a time relay input, the signal trigger method is optional (see parameter description 'input level
mode').
Detailed in the table below:
Signal
Input 1
Top point
Input 2
Switch point
Output access methods:
When E10 has soft limit function:
Shearing machine : the output OUT1 and OUT2 access relay coil externally.
E10
12
7
6
11
IN1
IN2
24V
OUT4
Bending Machine
0
X search ref-point
Y search ref-point
Page 8 of 28
E10 Operation Manual V1.15
10
9
8
5
OUT2
OUT3
OUT1
0V
Function
1
0
Top point
Switch point
0V
Shearing Machine
1
X search ref-point

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents