Nice O-Box Operation Instructions And Warnings page 10

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
The functions menu is divided into the three following sections: Codes; Cer-
tificates; Advanced (fig. 4). Important – The functions available in each sec-
tion vary according to the type of transmitter to be programmed.
–– CODES ––
This section enables entry of the codes of a transmitter, with the following func-
tions:
– Transmitter test: this function enables the user to test correct operation of
the transmitter and display the identity code and variable section of the RND
code.
– Change Code: this function enables the user to change the original identity
code of a transmitter.
IMPORTANT – To program several transmitters in sequence with progressive
codes, click on the icon "Program Sequence"; and compile two of the following
fields: "By code", "Step" (i.e. the increment of the code between one transmit-
ter and the other) and "N° codes"; then click on "Check". At this point the soft-
ware automatically complete the field left blank previously.
– Restore code: this function enables the user to restore the original (factory
set) identity code of a transmitter.
–– CERTIFICATES ––
This section enables entry of the certificates of a transmitter, with the following
functions:
– Set Certificates: this function enables the user to enter the "Certificate" of a
receiver in a transmitter. For each certificate the user can set the memorisation
in the transmitter in "Mode I" or "Mode II".
If memorisation is in mode "Mode II" (each key of the transmitter corresponds
to a specific function of the receiver) simply click on the item "Function" to
select the function number required and then select the key to be memorised
on the transmitter under "Buttons".
Note – The variety of controls available for transmitter memorisation depends on
the type of transmitter and model of control unit to be used for this transmitter. A
detailed list of controls is provided in the instruction manual of the control unit.
– Remove Certificates: this function enables the user to remove all certificates
of a transmitter.
8 – English
–– ADVANCED ––
This section enables entry of the protection codes and operating parame-
ters of a transmitter with the following functions:
– Set Codes: this function enables the user to personalise a transmitter, i.e.
modify the protection codes of "Installer", "Installation" and "Altera". In particu-
lar, "Altera" is compatible with the previous systems "FloR".
CAUTION! – Do not forget the new protection code otherwise the transmitter
will no longer be usable with this specific receiver.
– Advanced settings: This function enables entry of the following parameters:
J Number of blocks: enables modification of the number of identity code
repetitions when this code is transmitted. It is useful to modify this parameter
for special automations requiring faster response times to a command sent
than the default values
J Priority: enables replacement of an existing transmitter, maintaining the
same identity code. This is obtained by increasing the priority of the NEW
transmitter by one unit with respect to the OLD transmitter.
J Enable RND: this function enables the user to enable or disable manage-
ment of the variable section of the RND code.
J Enable code transfer: enables the option on the transmitter to transfer its
enable code to another transmitter.
J Copy between different models: enables the user to enable or disable
copying of the "enable codes" between different models of transmitter.
J Enable Repeater: enables the user to enable or disable management of
code repetition on receivers equipped with the "repeater" function.
Note – Click on "Factory settings" to set the default values of the parameters
listed above ("Advanced Settings").
– All Original: this function enables the user to restore all default settings on a
transmitter: this means that the original identity code is reset, all certificates are
removed and the default values of the various parameters are restored.
Important – For safety reasons, this function does not modify the value of the
protection codes, i.e. does not restore the factory settings.
– Guided Programming: this function enables the user to program a transmit-
ter using all sections described above in sequence.

Advertisement

Table of Contents
loading

This manual is also suitable for:

O-boxb

Table of Contents