Cabling Diagrams

Sun StorEdge A1000 and Netra st A1000 arrays
Sun StorEdge A3500 system

Sun StorEdge A1000 and Netra st A1000 Cabling Diagrams

Installing a Sun StorEdge A1000 or Netra st A1000
Storage Array
The storage arrays must be configured in pairs for the Oracle Solaris Cluster environment.
To cable the storage arrays, connect the differential SCSI cable between the node and the
storage array. Ensure that the entire SCSI bus length in each SCSI chain is less than 25 m. This
measurement includes the cables to both nodes, as well as the bus length that is internal to each
storage array, node, and host adapter.
is cabled in a Oracle Solaris Cluster environment.