Chore-Tronics Model 16 & 8 Control
*
{Note}
MT1554A
9/9/98
Alarms - continued
5. The maximum temperature limit is a backup to the limit established above, and
not relative to set point. If the first limit due to the fact it is a relative limit is
beyond an acceptable range, then the maximum temperature limit will activate
the alarm.
6. The relative low temperature and minimum temperature limits work in the same
way as the maximum limits.
7. High static pressure is the upper limit that you set to activate the alarm.
8. Low static pressure is the lower limit that you set to activate the alarm.
Both high and low limits must be exceeded for 30 seconds, and in
natural mode low static pressure alarm is disabled.
9. Alarm History will inform you of what the last 20 alarms were, and give you the
date and time the alarm was activated and the date and time the alarm situation
ceased (recovered).
To view the history information, use your down arrow.