Technical Data; General Details - Dräger PIR 3000 Instructions For Use Manual

Infrared gas transmitter
Table of Contents

Advertisement

Technical Data

General Details

Functional Principle
standard operating range
standard sensitivity
standard target gas categories
output signal
power supply
switch-on current (2 ms)
power consumption
connecting thread
material
weight
dimensions
environmental operating ranges
environmental storage ranges
IP rating
Compensated Infrared Absorption
0 – 100% LEL
0.16 mA/%LEL
methane, propane, ethylene
4 to 20 mA
10 to 30 V DC
≤0.5 A
≤2 W
M25x1.5 or 3/4" NPT
stainless steel SS 316
approx. 550 g
see "Dimensions" on page 25
o
–40 to 65
C
700 to 1300 hPa
0 to 100 % rel. hum.
o
–40 to 70
C
700 to 1300 hPa
0 to 100 % rel. hum., non-condensing
IP 66, IP 67, NEMA 4X&7