Test object
General tests
Battery Sense
Battery data
Right-left
Speed potentiometer, total
resistance
Speed potentiometer, resistance
range
Tool-dependent tests
Torque potentiometer, total
resistance (ASCS only)
Torque potentiometer, resistance
range (ASCS only)
All rights reserved by FEIN, especially in case of industrial rights registration.
FEIN retains all rights of disposal, such as copying and circulation.
ABOP 6, 10, 13-2
8. Troubleshooting (electrics)
Test method
Nominal value
Switch not pressed: > 1 MΩ
Passage
Switch pressed: < 10 Ω
< 10 Ω
Passage
Position 1: > 1 MΩ
Passage
Position 2: < 10 Ω
20 kΩ ±4 kΩ
Resistor
0 Ω to 20 kΩ ±4 kΩ
Resistor
(proportional to potentiometer travel)
Switch not pressed: 0 Ω
Switch pressed: 20 kΩ ±4 kΩ
100 kΩ ±10 kΩ
Resistor
0 kΩ to 90 kΩ ±10 kΩ
Resistor
(proportional to potentiometer travel)
Stage 1: 90 kΩ ±10 kΩ
Drilling stage: 0 kΩ
C-SC_CSSM
2012.08
Measurement
Measurement
line +
line -
Battery Sense
Pin 1
(yellow)
Battery data (blue)
Pin 6
Pin 4
Pin 5
Pin 4
Pin 2
Pin 4
Pin 3
Pin 7
Pin 9
Pin 7
Pin 8
68/69