Error Conditions; Enhanced Interface Controls; Password Protection - Emerson Rosemount X-STREAM O2 Transmitter Instruction Manual

Combustion flue gas transmitter
Table of Contents

Advertisement

Instruction Manual
IM-106-910C, Rev. 1.0
November 2009

Error Conditions

Xi Enhanced Interface
Controls

Password Protection

If there is an error condition at startup, an alarm message will be displayed.
Refer to Section 5: Troubleshooting to determine the cause of the error. Clear
the error and cycle power. The %O
less the alarm message.
The Xi Enhanced Interface can be used to change the software and alarm
settings, to adjust the high and low gas settings, and to initiate the calibration
sequence. Refer to the following control descriptions. Use the control keys on
the front panel of the Xi (Figure 4-1) to navigate and edit the Xi menu
(Figure 4-2).
MENU toggles between three Main menu options: System, Probe1, and
Probe2 (if available). The top level of the selected main menu is displayed.
DIAG toggles between the Alarms list of the three main menus. All faults and
warnings related to the selected main menu device are displayed.
ENTER saves newly entered data and returns you to previous menu level.
EXIT returns you to the previous menu level without saving newly entered
data. When navigating the menu tree, pressing EXIT returns you to the Main
menu.
UP/DOWN keys scroll up and down through menu items. During data entry
the Up/Down keys increment and decrement the data values.
LEFT arrow key returns you to the previous menu level. During data entry, the
left arrow key moves the cursor one digit to the left.
RIGHT arrow key advances you to the next menu level and, when a menu
item is highlighted, selects the item from a list of menu options. During data
entry, the right arrow key moves the cursor one digit to the right.
Beginning with Xi system software version 1.05 or higher the main display
and diagnostic screens of the Xi can be viewed at any time, but further access
and unauthorized configuration changes can be prevented by enabling a
password protection feature. However, the Xi is shipped with password
protection disabled.
Password protection can be enabled by selecting: System Main Menu>
Configure> LCD> Enable Password (see the Xi Menu, Figure 4-2).
The factory default upon enabling the password protection is ROSE, but the
password can consist of any 4 alpha/numeric characters.
If the user forgets the password, call Rosemount Analytical technical support
at 800-433-6076 to gain access to a master password.
A "Lock" icon will be displayed at the top right corner of the main display when
password protection is in effect.
The password protection will relock itself after a certain number of seconds
with no button pushes (defined as "revert time" in the same "LCD setup"
menu). Users can also force the front panel to be locked by selecting System
Main Menu> Log Off. The Log Off selection will perform no function if the
password feature is disabled.
The Xi has a "Reset" function that reestablishes all factory default conditions,
including the password protection feature, i.e. the password protection will fall
back to a disabled condition after a reset.
Hazardous Area
X-STREAM O
and temperature display should return
2
Transmitter
2
4-3