Tools Required for the Installation
T-10 TORX driver (set to 9 in-lbs)
T-20 TORX driver (set to 21 in-lbs)
5/16-inch torque wrench (set to 10 in-lbs)
1-inch torque wrench (set to 72 in-lbs)
ESD Equipment and Supplies Required for the Installation
ESD grounding wrist strap
5-ft grounding cord for wrist strap
2 x 4 ft conductive table mat and 15-ft grounding wire
ESD heel strap (for use with conductive floors)
Equipment Required for Post-Upgrade Adjustments
Equipment Type
Power meter
Power sensor, 2.4 mm
Adapter, 2.4 mm (f) to 2.4 mm (f)
RF cable, 2.4 mm (f) to 2.4 mm (f)
Overview of the Installation Procedure
Step 1. Remove the Outer and Inner Covers.
Step 2. Remove the Front Panel Assembly.
Step 3. Remove the 20 GHz Bottom Cables.
Step 4. Remove the Test Set Deck Front Panel.
Step 5. Remove the 20 GHz Top to Bottom Cables.
Step 6. Remove the 20 GHz Components.
Step 7. Install the 50 GHz Components.
Step 8. Install the 50 GHz Top to Bottom Cables.
Step 9. Assemble and Install the New Test Set Deck Front Panel.
Step 10. Install the 50 GHz Bottom Cables.
Step 11. Replace the Nameplate.
Step 12. Reinstall the Front Panel Assembly.
Step 13. Reinstall the Inner and Outer Covers.
Step 14. Enable Option F40.
Step 15. Perform Post-Upgrade Adjustments.
6
Description
Description
Model or
Part Number
E4418B/E4419B
8487A
11900B
85133C
Agilent Part Number
N/A
N/A
N/A
N/A
Agilent Part Number
9300-1367
9300-0980
9300-0797
9300-1308
Alternate Model or
Part Number
E4418A/E4419A
None
85056-60007
85133E
Installation Note N5230-90022