Install the New Test Set Deck Front Panel
Refer to
Figure 14
for this procedure. New parts are listed in
1. Place the new test set deck front panel, with the LED board and both new couplers
attached, onto the test set deck as shown.
2. Using a T-10 TORX driver, loosely reinstall the eight screws (items
the front panel to the test set deck. Once all screws have been loosely installed, torque each
of the eight screws to 9 in-lbs in the order indicated (
ensure proper alignment.
3. Reconnect the wrapped wire cable (item
Figure 14 Test Set Deck Front Panel Installation
Installation Note N5230-90022
Table 1 on page
through
x
) to the front-panel LED board.
4.
through
) to secure
). This is important to
21