Download Print this page

Lewmar AutoAnchor 150 Installation And Operation Instructions Manual page 8

Advertisement

PART 3 seT uP
3.1 TO eNTeR seT uP MOde:
The AA150 is automatically turned on when powered up.
+
To enter Set up Mode: Press and hold both buttons together.
The AutoAnchor version number (eg 1.31) is displayed briefly and
then - 1 - appears. This takes about 8 seconds.
3.2 seleCT FeeT OR MeTRes MeAsuReMeNT
The AA150 will flash between -1- and the current setting.
Use the or buttons to select Feet or Metres.
u1 = Metres
u2 = Feet
The selection is automatically saved 8 seconds after the last button
press and the display changes to -2-
3.3 seleCT The wINdlAss
- Default setting is Ch (Custom Chain Only Setting)
There are 3 windlass setting options:
1. A custom chain only windlass setting.
2. A custom rope and chain windlass setting for windlasses not on the
pre-set windass profile list.
3. Pre-programmed rope and chain windlass settings for windlasses on
the pre-set windlass profile list.
Follow the instructions below to select the option for your windlass.
The AA150 will flash between -2- and the current setting.
CusTOM ChAIN ONly wINdlAsses - default setting Ch
3.3.1
you need to know the length of chain per turn to enter these
settings. see Appendix 1 or the instructions overleaf to calculate
this.
If CH is not displayed, use the button to select CH at -2-.
The display will automatically change to -3- approximately 8 seconds
after the last button press.
Chain per Turn - Default setting is 11.8 inches (300mm).
The AA150 will flash between -3- and the current setting.
Use the or buttons to enter the chain per turn.
If you selected Feet at Item 1 the setting is entered in inches
(in increments of 0.10). See the table overleaf. If you selected Metres
it is entered in millimetres. The entry is automatically saved 8 seconds
after the last button press. PrG is briefly displayed.
12
- Default Setting is u1 (Metres)
3.3.2
CusTOM ROPe ANd ChAIN wINdlAsses
you need to know the length of chain per turn and the length of
rope per turn to enter these settings.
see the instructions overleaf to calculate this.
If CH is displayed, use the button to select rC at -2-.
If a number is displayed, use the button to select rC at -2-.
Chain per Turn - Default setting is 11.8 inches (300mm).
The display will automatically change to -3- (Chain per Turn).
The AA150 will flash between -3- and the current setting.
Use the or buttons to enter the chain per turn.
If you selected Feet (u2) at Item 1 the setting is entered in inches
(in increments of 0.10). See the table overleaf.
If you selected Metres (u1) it is entered in millimetres.
The display changes to -4- (Rope per Turn) approximately
The display changes to -4- (Rope per Turn) approximately
8 seconds after the last button press.
Rope per Turn - Default setting is 10.8 inches (275mm).
The AA150 will flash between -4- and the current setting.
Use the or buttons to enter the rope per turn in feet or
metres as you did for chain.
The entry is automatically saved 8 seconds after the last button press.
PrG is briefly displayed.
3.3.3
PRe-PROGRAMMed ROPe ANd ChAIN wINdlAsses
See Appendix 1 for the list of windlass profiles.
If CH is displayed, use the button to select rC at -2-.
If a number is displayed, use the button to select rC at -2-.
When rC is displayed. Press the button to access the windlass
profiles.
The display will flash between -2- and the current setting.
use the button to enter the windlass profile from the list in
Appendix 1.
Use the button to go back if necessary.
If you use this option there are no further settings.
your selection is automatically saved 8 seconds after the last button
press.
PrG is briefly displayed and the unit returns to the idle state.
13

Advertisement

loading