Troubleshooting(FAQ)
Circumstance
No signs of power
to the incubator.
When temperature
is too high /
When temperature
is too low
Alarm sounds with
"HI" indication
(abnormal high temp.)
Alarm sounds with
"LO" indication
(abnormal low temp.)
Humidity will not
go high enough.
The machine makes
some noise.
- A little noisy occurs from
the inside of circulation fan.
Dew foams in
the incubator.
Water leaks from
the machine.
Test the machine to be sure that the machine works without any problem before placing eggs in the machine.
Please ensure you remember how to use the machine and maybe re-read instructions.
DIGITAL INCUBATOR
6. Product Information
For more detailed self-diagnosis, see Rcom homepage
"SELF DIAGNOSIS" category.
Items to be confirmed
▶ Check electric cord is properly connected.
▶ Check if there is a power outage.
▶ Check whether the plug is damaged.
▶ Check the fuse.
▶ Check your setting temperature.
▶ Initialize the machine. [Refer to the page 13]
▶ Please check the bottom of machine is wet or not.
▶ Check air filter if there is dust on it.
▶ Check if room temperature is too high.
▶ Check if machine is exposed to the direct
rays of sun.
▶ In case of lowering temperature.
▶ Check if room temperature is too low.
(especially during night)
▶ please check the bottom of machine is wet
or not.
▶ Check your setting humidity.
▶ Close the door again after checking.
▶ Initialize the machine. [Refer to the page 13]
▶ Check if pumping is working. [Refer to the page 10]
▶ Check if outside temperature is too low.
▶ Check if there is any hatching dust such as
feather or eggs-shell in the machine FAN.
▶ A little noisy is not faulty.
▶ Check the machine is not placed too cold
circumstances.
▶ When you turn OFF machine and then turn
ON.
▶ In case of setting high humidity.
▶ Check if you did not place the water
container on the machine.
▶ Check that the machine placed on inclined
surface.
▶ Check if it is Dew condensation.
▶ When set as high humidity.
▶ When moved without taking out the water
tank for the humidifier unit.
▶ When humidity unit is not cleaned.
(2) Troubleshooting(FAQ)
Solutions
▶ Connect the cord again.
▶ Check the main socket with any other
electric appliances.
▶ Try to insert to another outlet.
▶ Change the Fuse. [Refer to the page 18]
▶ Set the temperature as required.
▶ Please remove moisture.
▶ Please put the water tank on the floor and use.
▶ Clean up the air filter [Refer to the page 17]
▶ Adjust room temperature 28℃ (82.4℉)
▶ Install machine without the direct rays of sun.
▶ Return machine to factory setting.
[Refer to page 13]
▶ Adjust room temperature 28℃ (82.4℉)
▶ Place thermometer inside of machine and
check if setting temperature is correct.
▶ Please remove moisture.
▶ Please put the water tank on the floor and use.
▶ Supply water.
▶ Check if silicon tube is blocked.
▶ Set the humidity again as required.
▶ Clean the humidity unit. [Refer to page. 16~17]
▶ Move the H&B in warm place
▶ Remove power and then open maintenance
cover to clean the FAN for air circulation.
[Refer to page 16~17]
▶ Adjust room temperature 28℃ (82.4℉)
▶ Dew condensation is a natural phenomenon
and not a malfunction of the device.
[Refer to the page 12]
▶ Please put the water tank on the floor and use.
▶ Place machine under a level surface.
▶ Dew condensation is a natural phenomenon
and not a malfunction of the device.
▶ Remove the remaining water in the humidity
unit using pipettes or syringe.
▶ Clean the dust(scale) from the humidifier
unit after use.
19