.Plastic shell dismantling for ABS wall mounted mode .The requirement of installation place .Installation requirement .Hot water pipe connection .Electric wiring V Safe use and maintain attention Safe use Maintenance Notes Common faults 4.Fault code description 5.Wiring diagram www.mycond.co.uk www.mycond.co.uk...
, instrumentation, telecommunications equipment, pharmaceuticals, information and other damp, rust, mildew and damage. 3.Principle Condenser Evaporator Filter Dry air Moist air Water Tank Compressor www.mycond.co.uk...
This process is exceptionally energy inefficient and rely on introducing outside air that is generally not suitable unless expensively heated. Drying by traditional heating involves continuously warming a stream of outside air on a constant in and out cycle. www.mycond.co.uk...
Vane control key CANCEL CONFIRM Useless button Useless button 1) ON/OFF button. Press this button to power on and off. In the ON mode, the remote controller displays the operation mode, fan speed, ambient temperature and the humidity . www.mycond.co.uk...
When the wired remote is damaged, disconnect the wired remote, infrared remote control unit to run through the unit. If the remote is damaged or missing, disconnect the Infrared remote control switch , by Turn on / Turn off switch to control the unit, the default mode for dehumidification mode! www.mycond.co.uk...
3.1. The unit can be installed in the balcony, roof, floor or any other convenient place and reliable load-bearing. 3.2.Airiness place. 3.3.No heat radiation or other heat source place 3.4.Should be set up shed against the snow in winter. 3.5.Barrier-free at the air inlet or outlet place. www.mycond.co.uk...
Page 11
Please remove the attachment. Unit installation, does not allow the right tilt, equipped with side outlet is Warning slightly lower, so the unit can be conducive to the normal drainage. 5mm height 10mm 5mm height www.mycond.co.uk...
The heating can be included as an option: either by hot water battery or by electric heating When not used in winter, please discharge water left inside the dehumidifier, in case of water system freezes, lead to coil distends to crack. www.mycond.co.uk...
1.5mm m 1.5mm 1.5mm 1.5mm 1.5mm 2.5mm 2.5mm 2.5mm 2.5mm 2.5mm 2.5mm Note: 1. used PVC insulated copper wire for above wiring 2. for installation requires, the line is longer than the maximum line length, please contact the company www.mycond.co.uk...
Skill to extend the life of air purification filters, if not used in a long time, put it into a plastic bag, sealed. Do not use of dehumidifiers exposed to water. This unit may leakage when watered, causing fire or electric shock. www.mycond.co.uk...
3.Power cables are not connected 3.Plug the power cord Replace the fuse Fuse blows 1.Clean the filter 1.Air filter fouling 2.Removal of obstructions 2.Doors and windows open Dehumidification little effect 3.Close doors and windows 3.Refrigerant leak. 4.Contact with the agent or factory repair www.mycond.co.uk...
5.Wiring diagram 5.1. Power phase sequence protection board description NO . Symbol Symbol Meaning Meaning Power Power input Power input Power input CON1 Power input Mk3077 Protection signal output Protection signal output Connect transformer power(12VAC)input 12V-IN 12V-IN 12V-OUT power(12VAC)output 12V-OUT www.mycond.co.uk...
Page 17
(short circuit: turn on cut: turn off) Hot water cycle pump effective for the unit with heating Hot water cycle Power input coil function. pump power output (220V/1PH/50Hz) (220V/1PH/50Hz) Compressor overload protector: Effective when the unit with external overload protector www.mycond.co.uk...
Page 18
Yellow Capacitance AC-N CN1CN2 Transformer NOTE: Infrared remote control switch. (short circuit: turn on cut: turn off) Hot water cycle pump effective for the unit with heating coil function. Hot water cycle Power input pump power output (220V/1PH/50Hz) (220V/1PH/50Hz) www.mycond.co.uk...
Page 19
(short circuit: turn on cut: turn off) : Auxiliary electric heatter overload PT switch(closed circuit) Hot water cycle pump Power input Water cycle : Infrared remote control switch effective for the unit with heating pump (380VAC/3PH/50Hz) coil function. : Mode select switch (220VAC) www.mycond.co.uk...
Need help?
Do you have a question about the ABS 7A and is the answer not in the manual?
Questions and answers