C onfiguring the Serial Hub with the Configuration Tool
4 2 B
The configuration tool is used to install the basic settings. Start the configuration tool
and all serial modems and settings may be viewed in the displayed list.
For this purpose, the configuration tool is started and finds all Serial Hubs in the same
network segment which it then lists in a table.
O verview Window
4 3 B
The configuration program locates all devices in its own network segment, even those
without a valid IP address.
If the settings (Properties) are to be carried out or changed under Windows 7, the
Configuration tool must be opened as Administrator. If the Tool has been started without
administrative rights this is displayed in the header.
Clicking on the column header in the overview, e.g. "IP address", sorts the devices in
ascending or descending order of the items in that column.
I tems in the Overview Window:
6 3 B
Name
IP Address
Subnet Mask
Gateway
MAC
Device Type
Version
Info
In Use
UDP-Port 3497
SIEMENS AG
Serial Hub name for better identification by means of a self-
explanatory text.
Current IP address
Current Subnet Mask
Current Gateway
Worldwide unique MAC address
Device Type
Current firmware version
Currently configured COM port (not available for Serial
Hubs)
If the entry is "YES", the device is in connection mode and
it is not possible to make changes to the settings.
If this entry is "NO", the device will no longer be found. It is
not connected, deactivated, or is behind a router that is
blocking the UDP port 3497.
Page 29 of 51
Manual 7XV5655-0BA00
C53000-G1176-C174-4