Troubles and solutions

Problem
Possible Cause
The UPS is not
switched on.
LED is not
Battery voltage
bright.
is too low.
Battery fault.
The UPS is
Power cord loose
always on
or no mains
battery mode.
power.
The UPS
continuously
Overload.
beeps.
Backup time
Battery voltage
too short.
is too low.
Overload.
Battery fault.
8
Solutions
Press the power switch again
to turn on the UPS.
Charge the battery at least
6 hours.
Replace the battery.
Check mains power and re-
plug the power cord.
Remove some unnecessary
loads. Before reconnecting
the equipment, please verify
that the load matches the
UPS capability specified in
the specifications.
Charge the battery at least
6 hours.
Remove some unnecessary
loads. Before reconnecting
equipment, please verify
that the load matches the
UPS capability specified in
the specifications.
Replace the battery.
Disposal of Old Electrical & Electronic Equipment
(Applicable in the European Union and other European countries with
separate collection systems)
This symbol on the product or on its packaging indicates that this product shall not be
treated as household waste.
Instead it shall be handed over to the applicable collection point for the recycling of
electrical and electronic equipment.
By ensuring this product is disposed of correctly, you will help prevent potential negative
consequences for the environment and human health, which could otherwise be caused
by inappropriate waste handling of this product.
The recycling of materials will help to conserve natural resources.
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Septu 600Septu 800Septu 1000

Table of Contents