3
1
Fig. №. 15
3.
Close the combustion chamber by inserting the upper front shaped piece (5).
4.
Insert carefully the inclined grate (6) into the fuel chamber. Lean its bottom part on the risers of the boiler section, and lean its bottom part
on the front section.
Fig. №. 16 Placement of the shaped pieces into the combustion chamber of the VIADRUS U22 Economy boiler
5.2.2
Mounting of claddings
1.
Shorting shutter connecting rod
2.
Screw M5 x 30
3.
Washer 5.3
4.
Nut M5
Fig. №. 17 Mounting of the connecting rod and the cladding bracket
2
1.
2.
3.
4.
5.
6.
Bottom left shaped piece
Bottom right shaped piece
Tertiary air nozzle
Upper rear shaped piece
Upper front shaped piece
Inclined grate
5.
Lowered bracket
6.
Washer 10.5
7.
Nut M10
13