Figure 3-5 Buttons On The Bop-2 - Siemens MICROMASTER 430 Manual

Hide thumbs Also See for MICROMASTER 430:
Table of Contents

Advertisement

Buttons on the BOP-2
Panel/Button
Figure 3-5
MICROMASTER 430
6SE6400-5AC00-0BP0
www.eltra-trade.com
Function
Indicates
The LCD displays the settings currently used by the converter.
Status
Pressing the button starts the converter. This button is disabled by
Start motor
default. To enable this button set P0700 = 1.
OFF1
at the selected ramp down rate. Disabled by default; to enable set
P0700 = 1.
Stop motor
OFF2 Pressing the button twice (or once long) causes the motor to
coast to a standstill.
This function is always enabled.
Manual
The customer terminal strip (CD S0) and the operating panel (BOP-
mode
2) are sources for commands and set values
The customer's terminal strip (CD S1) or the serial (US S) or field bus
Automatic
interface (e.g. PROFIBUS) are sources for commands and set
mode
values.
This button can be used to view additional information.
Pressing and holding the button for 2 seconds from any parameter
during operation, shows the following:
1.
DC link voltage (indicated by d – units V).
2.
Output current. (A)
3.
Output frequency (Hz)
4.
Output voltage (indicated by o – units V).
5.
The value selected in P0005 (If P0005 is set to show any of the
above (3, 4, or 5) then this will not be shown again).
Functions
Additional presses will toggle around the above displays.
Jump Function
From any parameter (rXXXX or PXXXX) a short press of the Fn
button will immediately jump to r0000, you can then change another
parameter, if required. Upon returning to r0000, pressing the Fn
button will return you to your starting point.
Quit
In case of a fault or alarm the
alarm message on the operator panel display.
Access
Pressing this button allows access to the parameters.
parameters
Increase
Pressing this button increases the displayed value.
value
Decrease
Pressing this button decreases the displayed value.
value
Buttons on the BOP-2
Operating Instructions
Effects
Pressing the button causes the motor to come to a standstill
button resets the fault or
3 Commissioning
39
info@eltra-trade.com