Troubleshooting with the SDP

Table 6-1 explains the
meaning of the various
states of the LEDs on
the SDP.
Table 6-1
Inverter
conditions indicated by the LEDs on the SDP
Mains not present
Ready to run
Inverter fault - other than the
ones listed below
Inverter running
Fault overcurrent
Fault overvoltage
Fault motor overtemperature
LEDs for indicating the drive
state
Off
On
approx. 0,3 s, flashing
approx. 1 s, twinkling
Fault inverter temperature
Warning current limit - both
LEDs twinkling same time
Other warnings - both LEDs
twinkling alternatively
Undervoltage trip /
undervoltage warning
Drive is not in ready state
ROM failure - Both LEDs
flashing same time
RAM failure - Both LEDs
flashing alternatively