1. INSTALLING AND PLACEMENT

1.1.
Mounting the "B" Type Wall Hung Boilers with Flue Duct
Caution: The mounting area and waste gas duct connection must conform the
instructions designated by Turkish Standards Institute and authorized bodies.
The wall hung boilers with flue ducts must not be mounted to areas with less than 8
m3 of volume and bedrooms, balcony, dusty environments, stairwells and random
empty areas in the building.
The waste gases that form due to combustion in wall hung boilers are exhausted by means of the
flue duct. Since the use of such devices at areas with air inlets and flue ducts not conforming the
specifications are dangeorus for human life, the Gas Company does not permit the use of gas.
The volume of your room must be equal to at least 0,6 m3 per each kW of the heat output of
your device. Practically you can estimate 1 m3 per each kW, for instance, for a device with
heat output of 24 kW, the volume of the room must be 24m3.
For supplying air for the room where your device is placed, an orifice must be made. (min
100cm2). The orifice must be made in a position both outside and inside the wall. Materials
which may obstruct the air flow should not be placed in front of the orifices.
These orifices must be preserved with unique grilled covers and no materials that may
obstruct the air flow must be put in front of it.
The air orifice must be on the wall or above the window. (As shown in the figure) .The orifice
below must be close to the floor and the orifice above must be close to the ceiling.
Or as it can be seen in the figure, one bottom orifice of minimum 150 m2 must be opened.
Minimum 150 cm
If these conditions are maintained, the air flow can be supplied from a place nearby :
The place nearby must be directly ventilated;
Only devices connected to the ventilation pipes must be installed in the area to be
ventilated;
The nearby place should not be a garage, barn or storage place where fuels or
combustibles are stored;
Due to the counter flow effect of the nearby area, it should be at an area of low pressure
compared to the area to be ventilated. (The counter flow in the area may arise due to
another device operating with no air inlets or the presence of another aspiration device or
fireplace.);
The air flow from the place nearby to the installing area to be ventilated can be free due
to permanent spaces. The said spaces can be provided by keeping a wide space
between door and floor.
BAYKAN ISI SIST.SAN.TIC.AS
INST AL L ING
EXAMPLE: ENABLING THE SPACE FOR AIR INLET
2
.
- 8 -