GasTech 24kW Baykan Starplus Manual

24-28-32 kw mono-thermic c type hermetic wall hung boilers, 24-28 kw mono-thermic b type flue duct wall hung boilers, 24 kw bithermic type-c hermetic wall hung boiler

Advertisement

BAYKAN WALL HUNG BOILER MANUAL
24-28-32 kW Mono-Thermic ''C" Type
24kW Baykan sun / 28kW Baykan sun / 32 kW Baykan sun
24-28 kW Mono-Thermic "B" Type
Our highly esteemed customers,
We would like to thank you for your thrust in our company; Baykan and your
decision for purchasing products of Baykan.
Our devices have been manufactured with the latest technology and they offer you
the best comfort of use and heating.
_______________________
Hermetic Wall Hung Boilers
24kW Baykan Starplus / 28kW Baykan Starplus
24kW Baykan moon / 28kW Baykan moon
Flue Duct Wall Hung Boilers
24kW Baykan starplus / 28kW Baykan starplus
24kW Baykan moon / 28kW Baykan moon
24kW Baykan sun / 28kW Baykan sun
24 kW Bithermic Type-"C"
Hermetic Wall Hung Boiler
24 kW Baykan sun
Baykan Is› Sist.San.Tic.As.
Haseyad Koop. Turgut Ozal Cad. No:147/1
34670 Ik›tell› Org.San. Bolg.
Istanbul - TURKIYE
+90 212 6712055
-
Fax +90 212 6712060
st
1
Edition – March 2005

Advertisement

Table of Contents
loading

Summary of Contents for GasTech 24kW Baykan Starplus

  • Page 1 _______________________ 24-28-32 kW Mono-Thermic ’’C” Type Hermetic Wall Hung Boilers 24kW Baykan Starplus / 28kW Baykan Starplus 24kW Baykan moon / 28kW Baykan moon 24kW Baykan sun / 28kW Baykan sun / 32 kW Baykan sun 24-28 kW Mono-Thermic “B” Type...
  • Page 2 USAGE 1. WARNINGS FOR THE USER The handbook of directives hereby is integral and supplementary part of the product thus preserve it • close to the device all times. Ensure that the manual is with the wall hung boiler when the device is sold or delivered to another user.
  • Page 3 3.1 CONTROL PANEL (star-starplus) Figure Nr. 13 34 5 6 7 8 “A” –DUCT CLEANING function with OFF/RESET 1 – Power Led switch and SUMMER-WINTER functions. “B” – Adjustment switch for setting the 2 – Led which displays there is flame temperature of water to be used “C”...
  • Page 4 Figure 14 “A” – OFF/RESET button/switch and DUCT 1 – Power voltage Led CLEANING function with SUMMER WINTER 2 – Flame indicating Led. functions. 3– The SCREEN where the temperatures of domes “B” –The switch for adjusting the temperature of water and heating water and extraordinary water to be used conditions are displayed.
  • Page 5 “A” – ON-OFF switch 1 – Displays the temperature of heat to be used or “B” – Tap water temperature adjustment switch menu pages. “C” – Heating water temperature adjustment button 2 – Displays the pressure of heating system or “D”...
  • Page 6 ADJUSTING THE TEMPERATURE OF WATER IN THE HEATING SYSTEM If the switch marked with letter “C” is rotated in clockwise direction, the temperature will increase, if it is turned counter clockwise, the temperature will decrease, the 3 changes made concerning temperature can be observed on the display screen marked with 3.After selecting the maximum operating temperature of heating system, the current temperature of heating system will be displayed, the adjustments made are obviously valid while working in winter mode.
  • Page 7 = The variable value determined by the user T base =The base temperature determined as 40° concerning the systems with radiators. 30° is the base temperature concerning the installations laid on floor. Concerning the HIGHER version only (the model with display screen) THE FUNCTION OF THIS In order to control with the external thermostat, it is sufficient to press SWITCH...
  • Page 8 If this mechanism is activated frequently, you must contact an authorized technical service immediately. E 06 or LED 70° THE CODE DISPLAYING THAT THE TEMPERATURE OF THE WATER DELIVERED EXCEEDS 90 C ° If the temperature of the water delivered exceeds 90°C, this code is displayed, this causes the wall hung boiler temporarily turn off, when the temperature goes below 90°C following this period, the wall hung boiler automatically turns on again.
  • Page 9 INST AL L ING 1. INSTALLING AND PLACEMENT 1.1. Mounting the “B” Type Wall Hung Boilers with Flue Duct Caution: The mounting area and waste gas duct connection must conform the instructions designated by Turkish Standards Institute and authorized bodies. The wall hung boilers with flue ducts must not be mounted to areas with less than 8 m3 of volume and bedrooms, balcony, dusty environments, stairwells and random empty areas in the building.
  • Page 10 EXAMPLEINDIRECT NATURAL VENTILATION EXAMPLE FOR AIR CIRCULATION THAT ARISES DUE TO THE DIFFERENCE OF DENSITY If air flow is insufficient, the combustion air may be supplied by an orifice from one or more rooms nearby the installing room by air orifices as seen in the figure 1.2.
  • Page 11 2. PLACEMENT OF THE WALL HUNG BOILER 2.1 MOUNTING THE WALL HUNG BOILER TO THE WALL fiek.6 Considering the dimensions of your device and by using the installing and mounting diagram on the packages, determine the positions of wall screws and sign them. NOTE: You should leave a space of at least 40 cm.
  • Page 12 ENSURE THAT THE GAS AND WATER CONNECTING PIPES HAVE NOT BEN USED FOR GROUNDING PURPOSES. IN SUCH CASES, DO NOT OPERATE THE WALL HUNG BOILER. DISCONNECT THE GROUNDING. SITUATIONS DANGEROUS FOR YOUR DEVICE MAY ARISE AT SUCH CASES. 2.3 ELECTRICITY CONNECTION The supply cable of your device is delivered to you as connected to the unit.
  • Page 13 FILLING THE WATER FOR CENTRAL HEATING SYSTEM After connecting electricity, gas and water connections, start filling the water for central heating system and circuit. This procedure must be performed with care. 3.1 Filling Operation for Baykan Sun Model Press “A” switch for running your wall hung boil (Figure13), the water pressure of central heating system will be displayed on the screen.
  • Page 14 They must be positioned at a visible place, they must be easily dismantled and dryable, so regular • heat expansions may be allowed. It must have the sampling unit with the appropriate properties and dimensions. The outlet of wall hung boiler must have the conditions of flue duct channel being vertical and not •...
  • Page 15 mush as the boiler at the top floor directly evacuates to atmosphere. The ancillary pipe of the common fume pipes separated into parts must be as high as the room at least and should not enter the collector with an angle less than 135°’...
  • Page 16 The waste gas duct connection must conform with the conditions specified in the regulations TSI and local gas distribution companies. WALL HUNG BOILERS WITH FLUE DUCTS The boiler must be connected to a duct before use. The duct of wall hung boiler must not be connected to stairwells or windows.
  • Page 17 CAUTION CONCENTRIC PIPE If concentric waste pipe assembly is shorter than specified; ……mt+bracket for BAYKAN 24KW ( P top ….Pa) ……mt+bracket for BAYKAN 28KW ( P top ….Pa) ..mt+bracket for BAYKAN 32KW ( P top ….Pa) A diaphragm must be used between the duct kiti and wall hung boiler outlet. Parallel pipe Connection If Parallel waste pipe assy.
  • Page 18 Fig.10 1- WASTE GAS KIT 2- DIAPHRAGM BAYKAN ISI SIST.SAN.TIC.AS - 17 -...
  • Page 19: Technical Data

    TECHNICAL DATA 1. TECHNICAL DATA BAYKAN star-Sunplus-moon-sun (base-medium-HI) (calculated in the conditions of environment as Pam=1013.25 mbar T.amb=15°C) TECHNICAL DATA Unit. 24OC 28OC 24SC 28SC 32SC 24BT Class II2H3+3B/P ------------ Nox Type Type C12-C32-C42-C52-C62 Type of Gas G30/31 Max. heat input 26.5 26.5 31.0...
  • Page 20 2. DIMENSIONS Fig.1 HERMETIC WALL HUNG BOILER WALL HUNG BOILER WITH FLUE DUCT 3. OPERATING DIAGRAM BAYKAN ISI SIST.SAN.TIC.AS.
  • Page 21 fiek.2 CONCERNING ALL MONOTHERMIC WALL HUNG BOILERS (24-28-32 kW Hermetic Wall Hung Boilers with Flue Duct Baykan sunplus-moon-sun) 1) Main exchanger 2) Boiler 3) Gas Valve 4) Motorized 3 way valve 5) Safety Valve 6) Filling Valve 7) Domestic Water Flow sensor 8) Plate Exchanger 9) Pump...
  • Page 22 Fig.3 24-28-32 kW Baykan Type C 24-28 kW Baykan Type B 24 kW Baykan eko bi-thermic AIR PRESSURE SWITCH 12) CIRCULATION PUMP SAFETY THERMOSTAT 13) GAS VALVE MAIN EXCHANGER 14) EXPANSION TANK COMBUSTION CHAMBER 15) BOILER COMBUSTION CHAMBER COVER 16) GROUND ELEKTRODE MOTORIZED 3 WAY VALVE 17) IGNITION ELECTRODE TEMPERATURE OF CENTRAL HEATING WATER...
  • Page 23 6. THE DIAGRAM OF THE ELECTRONIC CARD fiek.5 BAYKAN ISI SIST.SAN.TIC.AS.
  • Page 24 WARNINGS AND SAFETY INSTRUCTIONS For a safe use of your device in conformity with instructions, use your manual carefully. Comply with the operation and mounting instructions specified in the manual. The Manufacturing Company is not liable for the damages that arise due to faulty use. The manual must be preserved in order to be presented to the personnel sent for installing and service purposes and kept assuming it may be required in future.
  • Page 25 Your device must be serviced at least once a year. • The said service must be provided by Baykan Main Service Headquarters or Authorized • Technical Services. By means of the supplementary guarantee agreement, you can extend your warranty for •...
  • Page 26 CONTENTS WARNINGS PAGE. 2 TECHNICAL SPECIFICATIONS PAGE 3 II. 1 TABLE OF TECHNICAL DATA II. 2 EXTERIOR DIMENSIONS II. 3 OPERATION DIAGRAM II. 4 MAIN COMPONENTS OF THE WALL HUNG BOILER II. 5 GRAPH OF FLOW AND HIGHEST PUMPING POINT II.

This manual is also suitable for:

28kw baykan starplus24kw baykan sun24kw baykan moon28kw baykan sun32 kw baykan sun28kw baykan moon

Table of Contents