GasTech 24kW Baykan Starplus Manual page 4

24-28-32 kw mono-thermic c type hermetic wall hung boilers, 24-28 kw mono-thermic b type flue duct wall hung boilers, 24 kw bithermic type-c hermetic wall hung boiler
Table of Contents

Advertisement

Figure 14
"A" – OFF/RESET button/switch and DUCT
CLEANING function with SUMMER WINTER
functions.
"B" –The switch for adjusting the temperature of
water to be used
"C" –The adjustment switch for the central heating
set up.
"D" – MANOMETER (Pressure gauge)
FIRST TIME IGNITION OF THE DEVICE
-
After the Wall hung boiler is active, ( - - - ) will be displayed on the screen marked with 3 when the
selector marked with "A" is OFF, this indicates that there is voltage on the wall hung boiler.
You can Access to SUMMER or WINTER modes by rotating "A" selector.
If the wall hung boiler is in WINTER mode, the boiler will automatically ignite whenever there is need
for hot water or heating.
If the SUMMER mode is selected, the boiler will be on only when there is need for tap water.
-
Turn on a hot water tap, at which stage the wall hung boiler will start the ignition phase, if everything
goes correct, LED number 1 will glow, this indicates the flame, , if the boiler does not ignite, blocked
LED number 2 will glow and the letter E will be displayed on the screen, the number following the
letter E will specify the type of failure that arises. In order to remedy this situation, turn the "A"
selector to OFF/R position momentarily and turn it into SUMMER mode again.
CAUTION: Before the wall hung boiler specifies the blocking condition, the ignition circulation
will be repeated three times automatically.
ADJUSTING THE TEMPERATURE OF WATER TO BE USED
In order to adjust the temperature of the tap water, rotate the "B" switch clockwise for increasing the
temperature, rotate it counter clockwise to decrease the temperature, the change of temperature will be
displayed on screen marked with 3, the said temperature will only be displayed on the screen when
there is need for tap water. The adjustment made will be valid both when working in summer or winter
modes.
ADJUSTING THE TEMPERATURE OF WATER IN THE HEATING SYSTEM
If the switch marked with letter "C" is rotated in clockwise direction, the temperature will increase, if it is
turned counter clockwise, the temperature will decrease, the 3 changes made concerning temperature
can be observed on the display screen marked with 3.After selecting the maximum operating
temperature of heating system, the current temperature of heating system will be displayed, the
adjustments made are obviously valid while working in winter mode.
3.3 CONTROL PANEL OF SUN MODEL (sun)
Figure Nr. 15
BAYKAN ISI SIST.SAN.TIC. AS.
1
3
1 – Power voltage Led
2 – Flame indicating Led.
3– The SCREEN where the temperatures of domes
water and heating water and extraordinary
conditions are displayed.