ENSURE THAT THE GAS AND WATER CONNECTING PIPES HAVE NOT BEN USED FOR GROUNDING
PURPOSES. IN SUCH CASES, DO NOT OPERATE THE WALL HUNG BOILER. DISCONNECT THE
GROUNDING. SITUATIONS DANGEROUS FOR YOUR DEVICE MAY ARISE AT SUCH CASES.

2.3 ELECTRICITY CONNECTION

The supply cable of your device is delivered to you as connected to the unit. The external electricity
connection of the cable must be made by a qualified electrician in conformity with the regulations
and standards in effect.
The manufacturer company is not liable for the damages which may arise due to non-
standard electricity connection and grounding maps.
As electricity cables, use NYM 3x1,5 mm2 Phase, Neutral, soiling.
Use a 3 Amper fuse.
CAUTION: CONNECT YOUR DEVICE TO BIPOLAR SOCKETS.
Do not operate your device with multiple sockets and adapters.
If the electricity cables need to be replaced, the cables having the same properties and
specifications must be used. If there is a need for changing the cable, comply with the signs on the
main input connector.
Please connect the blue cable to the connector marked with 'N'.
Connect the brown cable to the connector marked with letter 'L'.
Connect the yellow/green cable to the connector signed with grounding sign.
While changing the cable, use the specified cables, H05VVF,H05-VVH2-F

2.4 ROOM THERMOSTAT CONNECTION

Have the room thermostat connection of
the device you purchased from Baykan
or delivered to you with the device
serviced by authorized technical service
personnel. Connect the cable from the
room thermostat to the poles of
connectors seen in diagram 7 correctly.
In case of connecting the external probe,
connect
the
thermostat to the poles of connectors
seen in diagram 7.
Caution: The device must be grounded.
The supply cable and voltage must be checked by the authorized staff, the power of wall hung
boiler must be measured and compared to the figures specified on the technical label of the wall
hung boiler and they must be equal. The cable must be appropriate for the power of wall hung
boiler.
NOTE: The manufacturer company is not liable for the damages and failures caused by
children and pets in the house.