If this mechanism is activated frequently, you must contact an authorized technical service
immediately.
E 06 or LED 70°
DELIVERED EXCEEDS 90 C °
If the temperature of the water delivered exceeds 90°C, this code is displayed, this causes the
wall hung boiler temporarily turn off, when the temperature goes below 90°C following this period,
the wall hung boiler automatically turns on again. (there is no need to use RESET in this case ).
If the problem carries on, it must be serviced by authorized technical service.
E 05 or LED 30° + LED 40°
MALFUNCTIONS OF THE MODULATOR
It appears when there is a case of malfunctioning of modulator, the wall hung boiler is not blocked
and keeps working. In this case, the connections of gas valves with the modulator must be
checked.
If the mentioned condition carries on, you must contact an authorized dealer.
E 07 or LED 80° + LED 60°
MALFUNCTIONS OF THE CIRCULATOR
It is displayed in case of a malfunction or failure of circulator. In order to remedy the blocking
condition of the circulator, you must press the RESET button marked with "E" concerning the
versions with display screen.
The button marked with "A" must be moved to reset position if it is the version with switches.
If the problem carries on, you must contact an authorized technical service.
BAYKAN ISI SIST.SAN.TIC. AS.
THE CODE DISPLAYING THAT THE TEMPERATURE OF THE WATER
- 23 -
THE CODE DISPLAYED CONCERNING THE
THE CODE DISPLAYED CONCERNING THE